Powered by GoogleTranslate

Inspection Detail

Inspection: 300651643 - C & B Mechanical Contractors, Inc.

Inspection Information - Office: Savannah Area Office

 

Inspection Nr: 300651643
Report ID: 0418400
Date Opened: 12/07/1999

Site Address:
C & B Mechanical Contractors, Inc.
Off Of Carpenter Rd. & Whiddon Mill Rd.
Tifton, GA 31794

Mailing Address:
Route 1, Box 267, Blountstown, FL 32424

Union Status: NonUnion

SIC:1623

NAICS: 0 


Inspection Type: Accident

Scope: Complete

Advanced Notice: N

Ownership: Private

Safety/Health: Safety

Close Conference: 02/23/2000

Planning Guide: Safety-Construction

Emphasis: S:Construction Fatalities

Case Closed: 06/25/2007


Related Activity
Type Activity Nr Safety Health
Accident 100901024
Violation Summary
Violations/Penalties Serious Willful Repeat Other Unclass Total
Initial Violations 4 1 5
Current Violations 3 2 5
Initial Penalty $8,750 $49,000 $0 $0 $0 $57,750
Current Penalty $3,000 $0 $0 $37,000 $0 $40,000
FTA Penalty $0 $0 $0 $0 $0 $0

Violation Items
# Citation ID Citaton Type Standard Cited Issuance Date Abatement Due Date Current Penalty Initial Penalty FTA Penalty Contest Latest Event Note
1. 01001 Serious 19260021 B02 05/10/2000 05/22/2000 $1,250 $2,500 $0 05/31/2000 F - Formal Settlement  
2. 01002 Serious 19260050 B 05/10/2000 05/22/2000 $500 $1,250 $0 05/31/2000 F - Formal Settlement  
3. 01003 Serious 19260651 K01 05/10/2000 05/16/2000 $1,250 $2,500 $0 05/31/2000 F - Formal Settlement  
4. 01004 Other 19260652 A01 05/10/2000 05/16/2000 $0 $2,500 $0 05/31/2000 F - Formal Settlement  
5. 02001 Other 19260550 A15 I 05/10/2000 05/16/2000 $37,000 $49,000 $0 05/31/2000 F - Formal Settlement  

Investigation Summary

Investigation Nr: 200900686
Event: 12/05/1999
electric shock - contact with overhead line thru boom

A crew of employees was laying 254-millimeter-diameter pipe for a city. The employees were using a 3.7-meter-long chain to lift the pipes. An overhead power line was located adjacent to the work area, but the employer had not contacted the electric utility owning the line. The day before the accident, an excavator had contacted the power line while the operator had been moving it through a gate that was about 61 meters from the work area. (The operator indicated that it was common practice to work near overhead power lines.) As the employees were laying the pipe on the day of the accident, one of them was touching the chain, which was attached to the excavator's bucket. When the operator lifted the bucket about 2.7 meters, the top of the boom elbow contacted the power line. The employee touching the chain was electrocuted. The employer had not adequately trained its employees in safe operations in the vicinity of overhead power lines. Additionally, on the morning of the accident, the site superintendent responsible for the overall jobsite instructed only one of the employees in the task to be performed.

Keywords: OVERHEAD POWER LINE, ELECTRICAL, BOOM, ELECTROCUTED, E C, EXCAVATOR

Investigated Inspection
# Inspection Age Sex Degree of Injury Nature of Injury Occupation
1 300651643 Fatality Electric Shock Miscellaneous material moving equipment operators
Back to Top

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.

Close