Inspection Detail
Inspection: 300622982 - Parsec, Inc.
Inspection Information - Office: Atlanta West Area Office
Site Address:
Parsec, Inc.
1600 Marietta Road, Gate 6
Atlanta, GA 30318
Mailing Address:
1100 Gest Street, Cincinnati, OH 45203
Union Status: NonUnion
SIC:4013
NAICS: 0
Inspection Type: Accident
Scope: Partial
Advanced Notice: N
Ownership: Private
Safety/Health: Safety
Close Conference: 03/10/1999
Emphasis:
Case Closed: 03/11/1999
| Type | Activity Nr | Safety | Health |
|---|---|---|---|
| Accident | 100200559 |
Investigation Summary
Employee #1 was found dead, sitting in a tire repair truck with all the doors and windows closed. The repair truck had a compressor used to inflate tires bolted to the floor directly behind the driver's seat. When Employee #1 was found, the truck was running and the compressor switch was in the 'on' position, but it had run out of fuel. It was determined that the exhaust pipe on the compressor had a small leak in the area where the hose fits into the compressor exhaust. On a previous shift, Employee #1 had stated that he had filled the truck's gas tank and the compressor with fuel. Employee #1 died from carbon monoxide fumes leaking from the small hole in the seal of the compressor exhaust hose.
Keywords: LEAK, COMPRESSOR, VAPOR, INHALATION, AIR CONTAMINATION, CHEMICAL VAPOR, OVEREXPOSURE, CARBON MONOXIDE, TRUCK DRIVER
| # | Inspection | Age | Sex | Degree of Injury | Nature of Injury | Occupation |
|---|---|---|---|---|---|---|
| 1 | 300622982 | Fatality | Asphyxia | Occupation not reported |