Inspection Detail
Inspection: 300611316 - M & M Pump & Supply Inc.
Inspection Information - Office: Fairview Heights Area Office
Site Address:
M & M Pump & Supply Inc.
307 Se 1st Street
Clay City, IL 62824
Mailing Address:
P.O. Box 525, Clay City, IL 62824
Union Status: NonUnion
SIC:1389
NAICS: 0
Inspection Type: Accident
Scope: Partial
Advanced Notice: N
Ownership: Private
Safety/Health: Safety
Close Conference: 06/26/2000
Emphasis:
Case Closed: 08/17/2000
| Type | Activity Nr | Safety | Health |
|---|---|---|---|
| Accident | 100840529 |
| Violations/Penalties | Serious | Willful | Repeat | Other | Unclass | Total |
|---|---|---|---|---|---|---|
| Initial Violations | 4 | 6 | 10 | |||
| Current Violations | 4 | 6 | 10 | |||
| Initial Penalty | $3,500 | $0 | $0 | $0 | $0 | $3,500 |
| Current Penalty | $3,500 | $0 | $0 | $0 | $0 | $3,500 |
| FTA Penalty | $0 | $0 | $0 | $0 | $0 | $0 |
| # | Citation ID | Citaton Type | Standard Cited | Issuance Date | Abatement Due Date | Current Penalty | Initial Penalty | FTA Penalty | Contest | Latest Event | Note |
|---|---|---|---|---|---|---|---|---|---|---|---|
| 1. | 01001 | Serious | 5A0001 | 07/25/2000 | 08/28/2000 | $3,500 | $3,500 | $0 | - | ||
| 2. | 01002A | Serious | 19100146 C02 | 07/25/2000 | 07/28/2000 | $0 | $0 | $0 | - | ||
| 3. | 01002B | Serious | 19100146 C04 | 07/25/2000 | 08/28/2000 | $0 | $0 | $0 | - | ||
| 4. | 01003 | Serious | 19100305 B02 | 07/25/2000 | 07/28/2000 | $0 | $0 | $0 | - | ||
| 5. | 01004 | Serious | 19101200 E01 | 07/25/2000 | 08/28/2000 | $0 | $0 | $0 | - | ||
| 6. | 02001 | Other | 19040002 A | 07/25/2000 | 07/28/2000 | $0 | $0 | $0 | - | ||
| 7. | 02002 | Other | 19100037 Q01 | 07/25/2000 | 07/28/2000 | $0 | $0 | $0 | - | ||
| 8. | 02003 | Other | 19100038 A01 | 07/25/2000 | 08/28/2000 | $0 | $0 | $0 | - | ||
| 9. | 02004 | Other | 19100132 D01 | 07/25/2000 | 08/28/2000 | $0 | $0 | $0 | - | ||
| 10. | 02005 | Other | 19100134 C01 | 07/25/2000 | 08/28/2000 | $0 | $0 | $0 | - | ||
| 11. | 02006 | Other | 19100178 L01 I | 07/25/2000 | 08/28/2000 | $0 | $0 | $0 | - |
Investigation Summary
Employee #1 was conducting an integrity test with compressed air on an indoor above-ground oil storage tank, model 210. The air was being introduced into the tank at 5 psig by an air compressor and a pressure assembly equipped with a gauge. Employee #1 was standing in front of the top plate when it suddenly blew off the tank and he was thrown through the corrugated metal wall of the building where the test was being performed. He was killed. The applicable industry standard, UL-142, steel above-ground tanks for flammable and combustible liquids, paragraph 39.2.1, required that the compressed air be set at between 1.5 and 2.5 psig.
Keywords: WORK RULES, OIL TANK, COMPRESSED AIR, TEST EQUIPMENT, EXPLOSION, HIGH PRESSURE, OIL WELL SERVICING, STRUCK BY, FLYING OBJECT
| # | Inspection | Age | Sex | Degree of Injury | Nature of Injury | Occupation |
|---|---|---|---|---|---|---|
| 1 | 300611316 | Fatality | Concussion | Laborers, except construction |
Translate