Powered by GoogleTranslate

Inspection Detail

Inspection: 300611316 - M & M Pump & Supply Inc.

Inspection Information - Office: Fairview Heights Area Office

 

Inspection Nr: 300611316
Report ID: 0524530
Date Opened: 05/31/2000

Site Address:
M & M Pump & Supply Inc.
307 Se 1st Street
Clay City, IL 62824

Mailing Address:
P.O. Box 525, Clay City, IL 62824

Union Status: NonUnion

SIC:1389

NAICS: 0 


Inspection Type: Accident

Scope: Partial

Advanced Notice: N

Ownership: Private

Safety/Health: Safety

Close Conference: 06/26/2000

Emphasis:

Case Closed: 08/17/2000


Related Activity
Type Activity Nr Safety Health
Accident 100840529
Violation Summary
Violations/Penalties Serious Willful Repeat Other Unclass Total
Initial Violations 4 6 10
Current Violations 4 6 10
Initial Penalty $3,500 $0 $0 $0 $0 $3,500
Current Penalty $3,500 $0 $0 $0 $0 $3,500
FTA Penalty $0 $0 $0 $0 $0 $0

Violation Items
# Citation ID Citaton Type Standard Cited Issuance Date Abatement Due Date Current Penalty Initial Penalty FTA Penalty Contest Latest Event Note
1. 01001 Serious 5A0001 07/25/2000 08/28/2000 $3,500 $3,500 $0 -  
2. 01002A Serious 19100146 C02 07/25/2000 07/28/2000 $0 $0 $0 -  
3. 01002B Serious 19100146 C04 07/25/2000 08/28/2000 $0 $0 $0 -  
4. 01003 Serious 19100305 B02 07/25/2000 07/28/2000 $0 $0 $0 -  
5. 01004 Serious 19101200 E01 07/25/2000 08/28/2000 $0 $0 $0 -  
6. 02001 Other 19040002 A 07/25/2000 07/28/2000 $0 $0 $0 -  
7. 02002 Other 19100037 Q01 07/25/2000 07/28/2000 $0 $0 $0 -  
8. 02003 Other 19100038 A01 07/25/2000 08/28/2000 $0 $0 $0 -  
9. 02004 Other 19100132 D01 07/25/2000 08/28/2000 $0 $0 $0 -  
10. 02005 Other 19100134 C01 07/25/2000 08/28/2000 $0 $0 $0 -  
11. 02006 Other 19100178 L01 I 07/25/2000 08/28/2000 $0 $0 $0 -  

Investigation Summary

Investigation Nr: 200840528
Event: 05/31/2000
Employee killed when oil tank explodes during test

Employee #1 was conducting an integrity test with compressed air on an indoor above-ground oil storage tank, model 210. The air was being introduced into the tank at 5 psig by an air compressor and a pressure assembly equipped with a gauge. Employee #1 was standing in front of the top plate when it suddenly blew off the tank and he was thrown through the corrugated metal wall of the building where the test was being performed. He was killed. The applicable industry standard, UL-142, steel above-ground tanks for flammable and combustible liquids, paragraph 39.2.1, required that the compressed air be set at between 1.5 and 2.5 psig.

Keywords: WORK RULES, OIL TANK, COMPRESSED AIR, TEST EQUIPMENT, EXPLOSION, HIGH PRESSURE, OIL WELL SERVICING, STRUCK BY, FLYING OBJECT

Investigated Inspection
# Inspection Age Sex Degree of Injury Nature of Injury Occupation
1 300611316 Fatality Concussion Laborers, except construction
Back to Top

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.

Close