Inspection Detail
Inspection: 300517927 - Energy Service Company Of Bowie Inc.
Inspection Information - Office: Fort Worth Area Office
Site Address:
Energy Service Company Of Bowie Inc.
Pioneer Rd & Pioneer Pkwy
Rhome, TX 76078
Mailing Address:
P.O. Box 1300, Bowie, TX 76230
Union Status: NonUnion
SIC:1389
NAICS: 0
Inspection Type: Accident
Scope: Partial
Advanced Notice: N
Ownership: Private
Safety/Health: Safety
Close Conference: 08/14/1998
Emphasis:
Case Closed: 09/08/1998
| Type | Activity Nr | Safety | Health |
|---|---|---|---|
| Accident | 100710433 |
| Violations/Penalties | Serious | Willful | Repeat | Other | Unclass | Total |
|---|---|---|---|---|---|---|
| Initial Violations | 2 | 2 | ||||
| Current Violations | ||||||
| Initial Penalty | $5,000 | $0 | $0 | $0 | $0 | $5,000 |
| Current Penalty | $0 | $0 | $0 | $0 | $0 | $0 |
| FTA Penalty | $0 | $0 | $0 | $0 | $0 | $0 |
| # | Citation ID | Citaton Type | Standard Cited | Issuance Date | Abatement Due Date | Current Penalty | Initial Penalty | FTA Penalty | Contest | Latest Event | Note |
|---|---|---|---|---|---|---|---|---|---|---|---|
| 1. | 01001 | Serious | 5A0001 | 08/14/1998 | 08/14/1998 | $2,500 | $2,500 | $0 | I - Informal Settlement | Citation has been deleted. | |
| 2. | 01002 | Serious | 5A0001 | 08/14/1998 | 08/14/1998 | $2,500 | $2,500 | $0 | I - Informal Settlement | Citation has been deleted. |
Investigation Summary
Employees #1 through #4, of the Energy Service Company, were working at an oil rig scheduled for temporary abandonment by the Railroad Commission. To be decommissioned, the well required a mechanical integrity test (MIT) to check for leaks in the casing. The crew from Energy Service were pulling tubing while waiting for the hot oil truck to pump hot water down the well to melt the paraffin. When the hot oil truck arrived on site, the driver, Employee #5, pulled up next to the well. He made the necessary connections, with Energy Service workers helping him to get hooked up. Before pumping the water down, the blowout protector (BOP) was opened. Oil and gas began to spew out. The other two Energy Services workers came over to assist in closing the BOP, but the extension arm to the BOP fell off. As the crew tried to reattach the extension arm, the oil and gas ignited. Employees #1 through #5 sustained multiple burns. Employees #1 through #4 were flown to the local burn center; Employee #5 was treated and released, but was subsequently admitted to the hospital for further treatment.
Keywords: FLAMMABLE VAPORS, WORK RULES, EXPLOSION, BLOWOUT--OIL WELL, EXTENSION HANDLE, BURN, FLAMMABLE LIQUID, FIRE, OIL WELL SERVICING, MECH MALFUNCTION
| # | Inspection | Age | Sex | Degree of Injury | Nature of Injury | Occupation |
|---|---|---|---|---|---|---|
| 1 | 300517927 | Hospitalized injury | Burn/Scald(Heat) | Occupation not reported | ||
| 2 | 300517927 | Hospitalized injury | Burn/Scald(Heat) | Occupation not reported | ||
| 3 | 300517927 | Hospitalized injury | Burn/Scald(Heat) | Occupation not reported | ||
| 4 | 300517927 | Hospitalized injury | Burn/Scald(Heat) | Occupation not reported |