Inspection Detail
Inspection: 300492618 - Columbus Utilities Of North Carolina
Inspection Information - Office: Fort Lauderdale Area Office
Site Address:
Columbus Utilities Of North Carolina
Angella And Grannell Sts
Key West, FL 33304
Mailing Address:
Rr-1 Box 286, Fair Bluff, NC 28439
Union Status: NonUnion
SIC:1623
NAICS: 0
Inspection Type: Accident
Scope: Complete
Advanced Notice: N
Ownership: Private
Safety/Health: Safety
Close Conference: 10/27/1997
Planning Guide: Safety-Construction
Emphasis:
Case Closed: 11/06/1997
Type | Activity Nr | Safety | Health |
---|---|---|---|
Accident | 100670751 |
Investigation Summary
Employee #1 was attempting to drive a pry bar through the epoxy liner of a manhole so that water from the installation process would drain into the invert. He fell through the manhole and landed in approximately 10 in. of hot water at approximately 180 degrees F. Employee #1 suffered burns to his chest, from which he later died.
Keywords: BURN, CHEST, INSTALLING, CONSTRUCTION, FALL, MANHOLE, HIGH TEMPERATURE, HOT WATER
# | Inspection | Age | Sex | Degree of Injury | Nature of Injury | Occupation |
---|---|---|---|---|---|---|
1 | 300492618 | Fatality | Burn/Scald(Heat) | Occupation not reported |