Powered by GoogleTranslate

Inspection Detail

Inspection: 300484771 - Calkins Midways Inc.

Inspection Information - Office: Appleton Area Office

 

Inspection Nr: 300484771
Report ID: 0521100
Date Opened: 07/30/1999

Site Address:
Calkins Midways Inc.
Langlade Fairgrounds Hwy 45
Antigo, WI 54409

Mailing Address:
Po Box 1534, Oshkosh, WI 54902

Union Status: NonUnion

SIC:7996

NAICS: 0 


Inspection Type: Accident

Scope: Partial

Advanced Notice: N

Ownership: Private

Safety/Health: Safety

Close Conference: 07/30/1999

Emphasis:

Case Closed: 01/05/2000


Related Activity
Type Activity Nr Safety Health
Accident 100650191
Violation Summary
Violations/Penalties Serious Willful Repeat Other Unclass Total
Initial Violations 4 4
Current Violations 4 4
Initial Penalty $7,750 $0 $0 $0 $0 $7,750
Current Penalty $7,000 $0 $0 $0 $0 $7,000
FTA Penalty $0 $0 $0 $0 $0 $0

Violation Items
# Citation ID Citaton Type Standard Cited Issuance Date Abatement Due Date Current Penalty Initial Penalty FTA Penalty Contest Latest Event Note
1. 01001 Serious 19100303 G02 I 08/24/1999 08/28/1999 $2,500 $2,500 $0 -  
2. 01002A Serious 19100304 F04 08/24/1999 08/28/1999 $2,500 $2,500 $0 -  
3. 01002B Serious 19100334 A02 I 08/24/1999 08/27/1999 $0 $0 $0 -  
4. 01002C Serious 19100304 A01 08/24/1999 08/28/1999 $0 $0 $0 -  
5. 01003A Serious 19100305 G01 III 08/24/1999 09/01/1999 $500 $1,000 $0 I - Informal Settlement  
6. 01003B Serious 19100305 G02 II 08/24/1999 09/01/1999 $0 $0 $0 -  
7. 01003C Serious 19100305 G02 III 08/24/1999 08/28/1999 $0 $0 $0 -  
8. 01004 Serious 19100332 B01 08/24/1999 08/30/1999 $1,500 $1,750 $0 I - Informal Settlement  

Investigation Summary

Investigation Nr: 200650315
Event: 07/29/1999
ELECTRIC SHOCK - CONTACT WITH ENERGIZED PARTS

An employee working for an amusement company was operating an amusement ride at a county fair. The ride (called an "Avalanche") was portable. It was scheduled to be at that location for only a few days. The employee contacted live parts of wiring for the ride and received an electric shock. He died of his injury 8 days after the accident. The control room for the ride had an electrical box enclosing two circuit breakers. The box had its cover removed, exposing live parts. In addition, the main control box had a hinged door that covered live parts. Employees would access this box at the start and end of the day to turn the ride on and off. There were many other electrical problems besides. For example, several equipment grounding conductors were found disconnected, and some grounding pins were missing from some attachment plugs. The ride was purchased by the amusement company in 1966, and the company performed much of the electrical work. The ride was frequently taken apart, transported to different sites, and reassembled. This apparently contributed to the wiring problems.

Keywords: AMUSE PARK/CARNIVAL, E GI V, ELECTRICAL, INADEQUATE MAINT, ELECTROCUTED, UNGUARDED LIVE PARTS, EQUIPMENT GROUNDING, ELECTRICAL BOX

Investigated Inspection
# Inspection Age Sex Degree of Injury Nature of Injury Occupation
1 300484771 Fatality Electric Shock Attendants, amusement and recreation facilities
Back to Top

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.

Close