Inspection Detail
Inspection: 300482270 - Jones Sign Co Inc
Inspection Information - Office: Appleton Area Office
Site Address:
Jones Sign Co Inc
Highway 41s, 14 Miles N Of Green Bay
Green Bay, WI 54307
Mailing Address:
711 Hinkle Rd, Po Box 2187, Green Bay, WI 54306
Union Status: NonUnion
SIC:7312
NAICS: 0
Inspection Type: Unprog Rel
Scope: Partial
Advanced Notice: N
Ownership: Private
Safety/Health: Safety
Close Conference: 10/20/1998
Emphasis: L:Fall
Case Closed: 04/01/1999
| Violations/Penalties | Serious | Willful | Repeat | Other | Unclass | Total |
|---|---|---|---|---|---|---|
| Initial Violations | 5 | 2 | 7 | |||
| Current Violations | 4 | 3 | 7 | |||
| Initial Penalty | $11,400 | $0 | $0 | $0 | $0 | $11,400 |
| Current Penalty | $5,800 | $0 | $0 | $0 | $0 | $5,800 |
| FTA Penalty | $0 | $0 | $0 | $0 | $0 | $0 |
| # | Citation ID | Citaton Type | Standard Cited | Issuance Date | Abatement Due Date | Current Penalty | Initial Penalty | FTA Penalty | Contest | Latest Event | Note |
|---|---|---|---|---|---|---|---|---|---|---|---|
| 1. | 01001 | Serious | 19100023 C01 | 10/22/1998 | 11/24/1998 | $1,600 | $3,000 | $0 | I - Informal Settlement | ||
| 2. | 01002A | Serious | 19100147 C04 I | 10/22/1998 | 03/31/1999 | $600 | $1,200 | $0 | P - Petition to Mod Abatement | ||
| 3. | 01002B | Serious | 19100147 C04 II | 10/22/1998 | 03/31/1999 | $0 | $0 | $0 | P - Petition to Mod Abatement | ||
| 4. | 01003 | Serious | 19100332 B01 | 10/22/1998 | 03/31/1999 | $1,100 | $2,100 | $0 | P - Petition to Mod Abatement | ||
| 5. | 01004 | Serious | 19100333 C03 IA1 | 10/22/1998 | 10/28/1998 | $2,500 | $3,000 | $0 | I - Informal Settlement | ||
| 6. | 01005A | Other | 19101200 E01 | 10/22/1998 | 11/24/1998 | $0 | $2,100 | $0 | I - Informal Settlement | ||
| 7. | 01005B | Other | 19101200 F05 II | 10/22/1998 | 11/24/1998 | $0 | $0 | $0 | I - Informal Settlement | ||
| 8. | 02001 | Other | 19100095 D01 | 10/22/1998 | 12/07/1998 | $0 | $0 | $0 | - | ||
| 9. | 02002 | Other | 19100132 D02 | 10/22/1998 | 12/31/1998 | $0 | $0 | $0 | I - Informal Settlement |
Investigation Summary
Two employees working for an outdoor advertising company were removing a 6.1-meter long section of rigid metal conduit from a billboard. An overhead power line was located within 3.3 meters of the billboard's catwalk platform, which was 11.6 meters above ground. The conduit contacted the 14.4-kilovolt power line, and both employees received electric shocks. One of the employees fell from the catwalk. Both employees were hospitalized with permanent, partially disabling injuries.
Keywords: OVERHEAD POWER LINE, ELECTRICAL, ELECTRIC SHOCK, FALL, ADVERTISING SIGN, METAL PIPE, E GI IB
| # | Inspection | Age | Sex | Degree of Injury | Nature of Injury | Occupation |
|---|---|---|---|---|---|---|
| 1 | 300482270 | Hospitalized injury | Electric Shock | Occupation not reported | ||
| 2 | 300482270 | Hospitalized injury | Electric Shock | Occupation not reported |