Powered by GoogleTranslate

Inspection Detail

Inspection: 300463114 - Morgantown National Supply, Inc.

Inspection Information - Office: Charleston Area Office

 

Inspection Nr: 300463114
Report ID: 0316400
Date Opened: 05/03/2002

Site Address:
Morgantown National Supply, Inc.
1526 Kanawha Boulevard East
Charleston, WV 25310

Mailing Address:
225 West Washington St, Suite 1900, Chicago, IL 60606

Union Status: Union

SIC:5082

NAICS: 0 


Inspection Type: Accident

Scope: Partial

Advanced Notice: N

Ownership: Private

Safety/Health: Safety

Close Conference: 05/03/2002

Emphasis:

Case Closed: 02/12/2003


Related Activity
Type Activity Nr Safety Health
Accident 100630557
Inspection 300463080
Violation Summary
Violations/Penalties Serious Willful Repeat Other Unclass Total
Initial Violations 1 1 2
Current Violations 1 1
Initial Penalty $3,150 $0 $0 $0 $2,250 $5,400
Current Penalty $0 $0 $0 $0 $1,800 $1,800
FTA Penalty $0 $0 $0 $0 $0 $0

Violation Items
# Citation ID Citation Type Standard Cited Issuance Date Abatement Due Date Current Penalty Initial Penalty FTA Penalty Contest Latest Event Note
1. 01001A Unclass 19101200 F05 I 06/27/2002 07/10/2002 $1,800 $2,250 $0 07/22/2002 F - Formal Settlement  
2. 01001B Unclass 19101200 F05 II 06/27/2002 07/10/2002 $0 $0 $0 07/22/2002 F - Formal Settlement  
3. 01002A Serious 19100133 A01 06/27/2002 07/10/2002 $0 $3,150 $0 07/22/2002 F - Formal Settlement Citation has been deleted.
4. 01002B Serious 19100138 A 06/27/2002 07/10/2002 $0 $0 $0 07/22/2002 F - Formal Settlement Citation has been deleted.

Investigation Summary

Investigation Nr: 200630754
Event: 04/18/2002
Employee died from exposure to chemical

Employee #1, a machinist, was instructed to clean machinery in the shop. A material known as Bulkie FW concentrate was dispensed from an unlabeled drum into a coffee can. Using a rag and wearing safety glasses but no gloves, the employee wiped the liquid cleaner onto the machinery, applying it at full strength. The material contains tetrapotassium pyrophosphate and sodium metasilicate which are corrosive materials. The material splashed onto the employee's face. He washed the product from his face and safety glasses and continued using the product for the next 2 and a half days. After experiencing a dry cough and shortness of breath, he received medical attention and was told that his lungs appeared to be chemically burned. The employee was sent to a pulmonary specialist, hospitalized, placed on oxygen, and evaluated for a lung transplant. The diagnosis was idiopathic pulmonary fibrosis (IPF). He later died from his injuries.

Keywords: LUNG, CLEANING, CHEMICAL VAPOR, OVEREXPOSURE, CHEMICAL

Investigated Inspection
# Inspection Age Sex Degree of Injury Nature of Injury Occupation
1 300463114 Fatality Burn(Chemical) Machinists
Back to Top

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.

Close