Inspection Detail
Inspection: 300451515 - Anchor Electric Inc
Inspection Information - Office: Tennessee Osha Nashville Office - Safety
Site Address:
Anchor Electric Inc
4755 Harding Rd.
Nashville, TN 37205
Mailing Address:
P.O. Box 1044, Madison, TN 37116
Union Status: NonUnion
SIC:1731
NAICS: 0
Inspection Type: Accident
Scope: Partial
Advanced Notice: N
Ownership: Private
Safety/Health: Safety
Close Conference: 12/24/1996
Planning Guide: Safety-Construction
Emphasis:
Case Closed: 01/08/1997
| Type | Activity Nr | Safety | Health |
|---|---|---|---|
| Accident | 100620046 |
Investigation Summary
Employee #1 and a coworker were using a Genie AWP-36 lift with a super straddle attachment to change a light bulb in a church. The lift was set up with only two outriggers, both on the same side of the lift. Employee #1 got into the lift and told his coworker to stand on one of the outriggers. Employee #1 had extended the lift to its full 36 ft elevation when it tilted and overturned on the side that had no outriggers. Employee #1 fell out of the lift, striking his head and body against the back of a church pew. He was killed.
Keywords: HEAD, OUTRIGGER, WORK RULES, CONSTRUCTION, FALL, FALL PROTECTION, ELEVATED WORK PLAT, AERIAL LIFT, OVERTURN, UNSTABLE POSITION
| # | Inspection | Age | Sex | Degree of Injury | Nature of Injury | Occupation |
|---|---|---|---|---|---|---|
| 1 | 300451515 | Fatality | Other | Electricians |
Translate