Inspection Detail
Inspection: 300398468 - Ace Plumbing & Sewer, Inc.
Inspection Information - Office: Baton Rouge Area Office
Site Address:
Ace Plumbing & Sewer, Inc.
5837 John Boucheaux
Abbeville, LA 70529
Mailing Address:
917 S. Fieldspan, Duson, LA 70529
Union Status: NonUnion
SIC:1711
NAICS: 0
Inspection Type: Accident
Scope: Complete
Advanced Notice: N
Ownership: Private
Safety/Health: Safety
Close Conference: 11/03/1997
Planning Guide: Safety-Construction
Emphasis:
Case Closed: 09/01/1998
| Type | Activity Nr | Safety | Health |
|---|---|---|---|
| Accident | 361125289 |
| Violations/Penalties | Serious | Willful | Repeat | Other | Unclass | Total |
|---|---|---|---|---|---|---|
| Initial Violations | 1 | 1 | 2 | |||
| Current Violations | 1 | 1 | 2 | |||
| Initial Penalty | $1,500 | $0 | $0 | $0 | $0 | $1,500 |
| Current Penalty | $1,500 | $0 | $0 | $0 | $0 | $1,500 |
| FTA Penalty | $0 | $0 | $0 | $0 | $0 | $0 |
| # | Citation ID | Citaton Type | Standard Cited | Issuance Date | Abatement Due Date | Current Penalty | Initial Penalty | FTA Penalty | Contest | Latest Event | Note |
|---|---|---|---|---|---|---|---|---|---|---|---|
| 1. | 01001 | Serious | 19260416 A01 | 01/05/1998 | 01/09/1998 | $1,500 | $1,500 | $0 | - | ||
| 2. | 02001 | Other | 19260050 C | 01/05/1998 | 01/09/1998 | $0 | $0 | $0 | - |
Investigation Summary
As two employees were using a boom truck to set a sewer tank into position, the boom contacted an overhead power line. One employee was electrocuted. The other employee received an electric shock and burns on his stomach and legs. He was hospitalized for his injuries.
Keywords: BURN, BOOM TRUCK, OVERHEAD POWER LINE, ELECTRICAL, BOOM, ELECTROCUTED, E GI IA, ELECTRIC SHOCK, TRUCK BOOM
| # | Inspection | Age | Sex | Degree of Injury | Nature of Injury | Occupation |
|---|---|---|---|---|---|---|
| 1 | 300398468 | Fatality | Electric Shock | Occupation not reported | ||
| 2 | 300398468 | Hospitalized injury | Electric Shock | Occupation not reported |