Inspection Detail
Inspection: 300375482 - Dana Glacier Vandervell
Inspection Information - Office: Iowa 0751910
Site Address:
Dana Glacier Vandervell
60428 Marne Road
Atlantic, IA 50022
Mailing Address:
, , 00000
Union Status: NonUnion
SIC:3714
NAICS: 0
Inspection Type: Referral
Scope: Partial
Advanced Notice: N
Ownership: Private
Safety/Health: Safety
Close Conference: 01/12/2000
Planning Guide: Safety-Manufacturing
Emphasis:
Case Closed: 01/15/2000
Type | Activity Nr | Safety | Health |
---|---|---|---|
Referral | 200520476 | Yes |
Investigation Summary
Employee #1 was checking the tension using a blank in a mechanical power press. His right hand was in the die area when the press cycled, amputating his index finger at the first knuckle and the tip of his middle finger.
Keywords: MAINTENANCE, AMPUTATED, POWER PRESS, FINGER, WORK RULES, DIE GUARD, POINT OF OPERATION, PRESS OPERATOR, PRESS, UNGUARDED
# | Inspection | Age | Sex | Degree of Injury | Nature of Injury | Occupation |
---|---|---|---|---|---|---|
1 | 300375482 | Non Hospitalized injury | Amputation | Occupation not reported |