Site Address:
The Whole Co, Inc. Dba Menasco
Camp Stover-Keska Lane
New Meadows, ID 83654
Mailing Address:
Box 349, Mccall, ID 83638
Union Status: NonUnion
SIC:1781
NAICS: 0
Inspection Type: Accident
Scope: Partial
Advanced Notice: N
Ownership: Private
Safety/Health: Safety
Close Conference: 07/03/1998
Emphasis:
Case Closed: 09/11/1998
| Type | Activity Nr | Safety | Health |
|---|---|---|---|
| Accident | 100230374 |
| Violations/Penalties | Serious | Willful | Repeat | Other | Unclass | Total |
|---|---|---|---|---|---|---|
| Initial Violations | 1 | 1 | 2 | |||
| Current Violations | 1 | 1 | 2 | |||
| Initial Penalty | $1,500 | $0 | $0 | $0 | $0 | $1,500 |
| Current Penalty | $1,500 | $0 | $0 | $0 | $0 | $1,500 |
| FTA Penalty | $0 | $0 | $0 | $0 | $0 | $0 |
| # | Citation ID | Citaton Type | Standard Cited | Issuance Date | Abatement Due Date | Current Penalty | Initial Penalty | FTA Penalty | Contest | Latest Event | Note |
|---|---|---|---|---|---|---|---|---|---|---|---|
| 1. | 01001A | Serious | 19260416 A01 | 08/26/1998 | 09/01/1998 | $1,500 | $1,500 | $0 | - | ||
| 2. | 01001B | Serious | 19260416 A03 | 08/26/1998 | 09/01/1998 | $0 | $0 | $0 | - | ||
| 3. | 02001 | Other | 19040008 A | 08/26/1998 | 09/01/1998 | $0 | $0 | $0 | - |
Investigation Summary
Two employees were drilling a water well near an overhead power line. They swung the boom of the drill around the vehicle, and it contacted the power line. One employee was electrocuted. The other received an electric shock. (The second employee was not listed on an injury line on the original form.)
Keywords: OVERHEAD POWER LINE, ELECTRICAL, BOOM, ELECTROCUTED, E GI IA, DRILL RIG--NON-OIL, ELECTRIC SHOCK
| # | Inspection | Age | Sex | Degree of Injury | Nature of Injury | Occupation |
|---|---|---|---|---|---|---|
| 1 | 300209806 | Fatality | Electric Shock | Drillers, earth |