Powered by GoogleTranslate

Inspection Detail

Inspection: 300181732 - Murray Guard, Inc.

Inspection Information - Office: Corpus Christi Area Office

 

Inspection Nr: 300181732
Report ID: 0626000
Date Opened: 05/30/1996

Site Address:
Murray Guard, Inc.
1801 Nueces Bay Blvd.
Corpus Christi, TX 78407

Mailing Address:
410 S. Padre Island Dr., Corpus Christi, TX 78405

Union Status: NonUnion

SIC:7381

NAICS: 0 


Inspection Type: Unprog Rel

Scope: Partial

Advanced Notice: N

Ownership: Private

Safety/Health: Health

Close Conference: 07/03/1996

Emphasis:

Case Closed: 09/24/1996


Related Activity
Type Activity Nr Safety Health
Accident 100210012
Violation Summary
Violations/Penalties Serious Willful Repeat Other Unclass Total
Initial Violations 1 1
Current Violations 1 1
Initial Penalty $1,875 $0 $0 $0 $0 $1,875
Current Penalty $1,125 $0 $0 $0 $0 $1,125
FTA Penalty $0 $0 $0 $0 $0 $0

Violation Items
# Citation ID Citaton Type Standard Cited Issuance Date Abatement Due Date Current Penalty Initial Penalty FTA Penalty Contest Latest Event Note
1. 01001 Serious 19100119 H03 II 08/06/1996 08/11/1996 $1,125 $1,875 $0 I - Informal Settlement  

Investigation Summary

Investigation Nr: 200210052
Event: 05/25/1996
Employees injured after inhaling hydrogen fluoride

Employees #1 through #7 were working between one and four blocks away from an alkylation unit, which was operating as usual. An worker in that unit had been instructed to block in the flow transmitter 83 FC 102, which was connected to a 2 in. internal hydrogen fluoride regeneration line at an orifice plate. He was to close the two 90 degree block valves, which were stubbed off the high and low sides of the flanged orifice plate, and open the two 90 degree bleed valves on both the high and low sides of the differential pressure instrument. According to the operators, there were no valve handles on the two 90 degree block valves because of physical interference from adjacent equipment. The worker that was to block in the instrument apparently failed to close one or both of the block valves before he opened the bleed valves. A vapor cloud of hydrogen fluoride developed. The leak continued for about five minutes, with the release of approximately 100 lb of hydrogen fluoride. A water deluge was used to minimize the vapor cloud. No injuries were reported in the alkylation unit, but Employees #1 through #7, who were working downwind, sustained minor inhalation injuries. On May 26, 1996, Citgo reported that all but two of the seven employees would be released from Memorial Hospital. One of those hospitalized was a gate guard, of Murray Security, who was stationed at the north entrance to the Citgo Refinery.

Keywords: LEAK, WORK RULES, INHALATION, VALVE, CHEMICAL BURN, HYDROGEN FLUORIDE, CHEMICAL VAPOR, ACCIDENTAL DISCHARGE, REFINERY, CHEMICAL

Investigated Inspection
# Inspection Age Sex Degree of Injury Nature of Injury Occupation
1 300181732 Hospitalized injury Burn(Chemical) Occupation not reported
Back to Top

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.

Close