Inspection Detail
Inspection: 300058435 - Mid-American Contractors
Inspection Information - Office: Omaha Area Office
Site Address:
Mid-American Contractors
20214 Veterans Drive
Elkhorn, NE 68022
Mailing Address:
P.O. Box 34146, Omaha, NE 68134
Union Status: NonUnion
SIC:1799
NAICS: 0
Inspection Type: Referral
Scope: Complete
Advanced Notice: N
Ownership: Private
Safety/Health: Safety
Close Conference: 05/09/2000
Planning Guide: Safety-Construction
Emphasis: S:Construction, S:Construction Fatalities
Case Closed: 05/24/2000
| Type | Activity Nr | Safety | Health |
|---|---|---|---|
| Referral | 200051944 | Yes |
| Violations/Penalties | Serious | Willful | Repeat | Other | Unclass | Total |
|---|---|---|---|---|---|---|
| Initial Violations | 1 | 1 | ||||
| Current Violations | 1 | 1 | ||||
| Initial Penalty | $600 | $0 | $0 | $0 | $0 | $600 |
| Current Penalty | $600 | $0 | $0 | $0 | $0 | $600 |
| FTA Penalty | $0 | $0 | $0 | $0 | $0 | $0 |
| # | Citation ID | Citaton Type | Standard Cited | Issuance Date | Abatement Due Date | Current Penalty | Initial Penalty | FTA Penalty | Contest | Latest Event | Note |
|---|---|---|---|---|---|---|---|---|---|---|---|
| 1. | 01001 | Serious | 5A0001 | 05/09/2000 | 05/24/2000 | $600 | $600 | $0 | - |
Investigation Summary
The employer's crew was conducting a horizontal boring operation requiring them to drill approximately 4 ft underground for a distance of approximately 300 ft. The company had located the utilities by contacting the state's "one call" number, and had exposed the utilities where they would cross them. The first bore shot was thwarted by an obstruction and they had to pull out and try another spot approximately 2 to 4 ft south of the original point of entry. The second bore shot went well, but the job required attaching a reamer and a copper cable to the boring apparatus and pulling them back through. The 8 in. wide reamer was twice the diameter of the bore drill and it struck a gas line and a sewer line on its return to the boring machine. The natural gas traveled through the gas line and into an adjacent building, which exploded and ignited into flames. The employer had failed on the second shot to expose the utility at the point where the boring device was to cross it, and therefore was unaware of the change in elevation of the gas line.
Keywords: FLAMMABLE VAPORS, WORK RULES, FIRE, STRUCK AGAINST, CONSTRUCTION, NATURAL GAS, RUPTURE, EXPLOSION, BORING MACHINE, INATTENTION
| # | Inspection | Age | Sex | Degree of Injury | Nature of Injury | Occupation |
|---|---|---|---|---|---|---|
| 1 | 300058435 | Occupation Not Listed |