Powered by GoogleTranslate

Inspection Detail

Inspection: 300050721 - Scott Enterprises, Inc.

Inspection Information - Office: Omaha Area Office

 

Inspection Nr: 300050721
Report ID: 0728900
Date Opened: 07/09/1997

Site Address:
Scott Enterprises, Inc.
4315 Emile Street
Omaha, NE 68131

Mailing Address:
10547 Bondesson Court, Omaha, NE 68122

Union Status: NonUnion

SIC:1761

NAICS: 0 


Inspection Type: Complaint

Scope: Partial

Advanced Notice: N

Ownership: Private

Safety/Health: Safety

Close Conference: 09/24/1997

Planning Guide: Safety-Construction

Emphasis:

Case Closed: 10/27/1997


Related Activity
Type Activity Nr Safety Health
Complaint 200053163 Yes
Violation Summary
Violations/Penalties Serious Willful Repeat Other Unclass Total
Initial Violations 1 1
Current Violations 1 1
Initial Penalty $625 $0 $0 $0 $0 $625
Current Penalty $0 $0 $0 $312 $0 $312
FTA Penalty $0 $0 $0 $0 $0 $0

Violation Items
# Citation ID Citaton Type Standard Cited Issuance Date Abatement Due Date Current Penalty Initial Penalty FTA Penalty Contest Latest Event Note
1. 01001 Other 19101200 E02 II 09/24/1997 10/27/1997 $312 $625 $0 I - Informal Settlement  

Investigation Summary

Investigation Nr: 200050201
Event: 07/08/1997
Employee burned when flammable adhesive ignites

Employee #1 and three coworkers, of Scott Enterprises, were installing a temporary roof on the fourth floor of a building at the University of Nebraska Medical Center. They were using flammable adhesives to put down rubber matting when something ignited the flammable vapors and caused a large flash fire. Employee #1 sustained first-degree burns on his neck and right ear, and second-degree burns on his right forearm and on a knuckle. He was temporarily trapped on a corner of the roof, and his lanyard was burned. Coworkers from his own company and employees of other contractors were able to rescue him and put out the fire. The source of ignition appears to have been from welding that was being done by iron workers on other floors.

Keywords: BURN, INSTALLING, ROOF, FLAMMABLE VAPORS, WORK RULES, FIRE, FOREARM, CONSTRUCTION, WELDING, CHEMICAL VAPOR

Investigated Inspection
# Inspection Age Sex Degree of Injury Nature of Injury Occupation
1 300050721 Non Hospitalized injury Burn/Scald(Heat) Roofers
Back to Top

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.