Inspection Detail
Inspection: 300038882 - Spraylat Corp
Inspection Information - Office: Chicago South Area Office
Site Address:
Spraylat Corp
1701 E. 122nd St
Chicago, IL 60633
Mailing Address:
716 South Columbus Avenue, Mt. Vernon, NY 10550
Union Status: Union
SIC:2869
NAICS: 0
Inspection Type: Accident
Scope: Partial
Advanced Notice: N
Ownership: Private
Safety/Health: Safety
Close Conference: 04/21/1998
Emphasis:
Case Closed: 05/27/1998
| Type | Activity Nr | Safety | Health |
|---|---|---|---|
| Accident | 100030337 | ||
| Referral | 200031029 | Yes |
| Violations/Penalties | Serious | Willful | Repeat | Other | Unclass | Total |
|---|---|---|---|---|---|---|
| Initial Violations | 6 | 1 | 7 | |||
| Current Violations | 3 | 2 | 5 | |||
| Initial Penalty | $9,171 | $0 | $0 | $0 | $0 | $9,171 |
| Current Penalty | $3,000 | $0 | $0 | $1,000 | $0 | $4,000 |
| FTA Penalty | $0 | $0 | $0 | $0 | $0 | $0 |
| # | Citation ID | Citaton Type | Standard Cited | Issuance Date | Abatement Due Date | Current Penalty | Initial Penalty | FTA Penalty | Contest | Latest Event | Note |
|---|---|---|---|---|---|---|---|---|---|---|---|
| 1. | 01001 | Serious | 19100024 B | 04/23/1998 | 04/27/1998 | $0 | $956 | $0 | I - Informal Settlement | Citation has been deleted. | |
| 2. | 01002 | Serious | 19100132 D01 | 04/23/1998 | 04/27/1998 | $1,000 | $1,875 | $0 | I - Informal Settlement | ||
| 3. | 01003 | Other | 19100145 C02 I | 04/23/1998 | 04/27/1998 | $1,000 | $1,875 | $0 | I - Informal Settlement | ||
| 4. | 01004 | Serious | 19100151 C | 04/23/1998 | 04/27/1998 | $1,000 | $1,275 | $0 | I - Informal Settlement | ||
| 5. | 01005 | Serious | 19100303 G02 IA | 04/23/1998 | 04/27/1998 | $1,595 | $1,595 | $0 | I - Informal Settlement | Citation has been deleted. | |
| 6. | 01006 | Serious | 19100332 B01 | 04/23/1998 | 04/27/1998 | $1,000 | $1,595 | $0 | I - Informal Settlement | ||
| 7. | 02001 | Other | 19101200 F05 II | 04/23/1998 | 04/28/1998 | $0 | $0 | $0 | I - Informal Settlement |
Investigation Summary
Employee #1 spilled a can of solvent inside the electrical room of the plant. The solvent exploded into flame and Employee #1 suffered fatal burns.
Keywords: BURN, VAPOR, FLAMMABLE LIQUID, FLAMMABLE VAPORS, FIRE, CHEMICAL BURN, CLEANING FLUID, CHEMICAL VAPOR, CHEMICAL
| # | Inspection | Age | Sex | Degree of Injury | Nature of Injury | Occupation |
|---|---|---|---|---|---|---|
| 1 | 300038882 | Fatality | Burn(Chemical) | Occupation not reported |
Translate