Inspection Detail
Inspection: 300030186 - Perma-Seal Basement Waterproofing
Inspection Information - Office: Chicago South Area Office
Site Address:
Perma-Seal Basement Waterproofing
15140 S. Evers St.
Dolton, IL 60419
Mailing Address:
513 Rogers Street, Downers Grove, IL 60515
Union Status: NonUnion
SIC:1799
NAICS: 0
Inspection Type: Accident
Scope: Partial
Advanced Notice: N
Ownership: Private
Safety/Health: Safety
Close Conference: 06/07/1996
Planning Guide: Safety-Construction
Emphasis:
Case Closed: 08/01/1996
Type | Activity Nr | Safety | Health |
---|---|---|---|
Accident | 361803943 |
Violations/Penalties | Serious | Willful | Repeat | Other | Unclass | Total |
---|---|---|---|---|---|---|
Initial Violations | 1 | 1 | ||||
Current Violations | 1 | 1 | ||||
Initial Penalty | $3,500 | $0 | $0 | $0 | $0 | $3,500 |
Current Penalty | $2,500 | $0 | $0 | $0 | $0 | $2,500 |
FTA Penalty | $0 | $0 | $0 | $0 | $0 | $0 |
# | Citation ID | Citaton Type | Standard Cited | Issuance Date | Abatement Due Date | Current Penalty | Initial Penalty | FTA Penalty | Contest | Latest Event | Note |
---|---|---|---|---|---|---|---|---|---|---|---|
1. | 01001A | Serious | 19260021 B02 | 07/08/1996 | 07/25/1996 | $2,500 | $3,500 | $0 | I - Informal Settlement | ||
2. | 01001B | Serious | 19260416 E01 | 07/08/1996 | 07/11/1996 | $0 | $0 | $0 | - | ||
3. | 01001C | Serious | 19260416 F08 | 07/08/1996 | 07/11/1996 | $0 | $0 | $0 | - |
Investigation Summary
An employee was using a Bosch chipping hammer (Model No. 11305) to break some concrete behind a panel wall in the basement of a home. A bare conductor on the tool contacted a metal heating duct in the basement. The employee, who was apparently touching the heating duct, was electrocuted.
Keywords: E GI V, ELEC INSULATION, ELECTRICAL, ELECTROCUTED, GROUND FAULT, ELECTRIC CORD
# | Inspection | Age | Sex | Degree of Injury | Nature of Injury | Occupation |
---|---|---|---|---|---|---|
1 | 300030186 | Fatality | Electric Shock | Construction laborers |