Powered by GoogleTranslate

Inspection Detail

Inspection: 2985851 - R. Jones Drywall Corp.

Inspection Information - Office: Nc Department Of Labor - Raleigh

 

Inspection Nr: 2985851
Report ID: 0453710
Date Opened: 08/23/1989

Site Address:
R. Jones Drywall Corp.
Dan Allen Dr. & Faucette Dr., Ncsu Campus
Raleigh, NC 27606

Mailing Address:
P. O. Box 116, Fayetteville, NC 28301

Union Status: NonUnion

SIC:1742

NAICS: 0 


Inspection Type: Accident

Scope: Partial

Advanced Notice: N

Ownership: Private

Safety/Health: Safety

Close Conference: 09/21/1989

Planning Guide: Safety-Construction

Emphasis:

Case Closed: 10/30/1990


Related Activity
Type Activity Nr Safety Health
Accident 360487433
Violation Summary
Violations/Penalties Serious Willful Repeat Other Unclass Total
Initial Violations 3 3
Current Violations 3 3
Initial Penalty $630 $0 $0 $0 $0 $630
Current Penalty $630 $0 $0 $0 $0 $630
FTA Penalty $0 $0 $0 $0 $0 $0

Violation Items
# Citation ID Citaton Type Standard Cited Issuance Date Abatement Due Date Current Penalty Initial Penalty FTA Penalty Contest Latest Event Note
1. 01001 Serious 19260021 B02 12/04/1989 12/11/1989 $210 $210 $0 -  
2. 01002A Serious 19260028 A 12/04/1989 12/11/1989 $210 $210 $0 -  
3. 01002B Serious 19260451 D10 12/04/1989 12/11/1989 $0 $0 $0 -  
4. 01003A Serious 19260451 A07 12/04/1989 12/11/1989 $210 $210 $0 -  
5. 01003B Serious 19260451 D03 12/04/1989 12/11/1989 $0 $0 $0 -  
6. 01003C Serious 19260451 D06 12/04/1989 12/11/1989 $0 $0 $0 -  

Investigation Summary

Investigation Nr: 14253108
Event: 08/23/1989
SIX INJURED IN SCAFFOLD COLLASPE

At 9:05 a.m. on August 23, 1989, six employees were on a 38-ft-high by 21-ft-long tubular welded frame scaffold erected outside, adjacent to a three story building. It was built of 5-ft-wide by 6-ft-4-in.-high walk through frames erected on compact soil and 2-in. by 10-in. sills, with leveling screw jacks under each leg. Work platforms, fully decked with 2-in. by 10-in. lumber were located at each 6 ft-4 in. interval of the height. Employees #1, 2 and 3 were on the 2nd and 3rd levels, stocking the scaffold with brick and mortar, and repairing common brick on the exterior of the building. Employees #4, 5 and 6 were on the 4th and 5th levels hanging insulated sheathing boards. The scaffold collapsed, apparently without warning. Employees fell anywhere from 13 to 32 ft. Employee #4 was hospitalized overnight with multiple injuries including internal bruises. Employees #1, 2, 3, 5 and 6 suffered abrasions, bruises, and/or cuts, but were released from the hospital's emergency room.

Keywords: CONCUSSION, FALL, SCAFFOLD, BRICK, ABRASION, CONTUSION, SCAFFOLD COLLAPSE

Investigated Inspection
# Inspection Age Sex Degree of Injury Nature of Injury Occupation
1 2985851 Occupation Not Listed
Back to Top

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.

Close