Powered by GoogleTranslate

Inspection Detail

Inspection: 2904373 - Mr P'S

Inspection Information - Office: Minnesota Department Of Labor And Industry

 

Inspection Nr: 2904373
Report ID: 0552700
Date Opened: 08/14/1985

Site Address:
Mr P'S
1402 North Broadway
Rochester, MN 55904

Mailing Address:
1201 South Broadway, Rochester, MN 55904

Union Status: NonUnion

SIC:5411

NAICS: 0 


Inspection Type: Accident

Scope: Partial

Advanced Notice: N

Ownership: Private

Safety/Health: Safety

Close Conference: 08/14/1985

Emphasis:

Case Closed: 11/24/1986


Related Activity
Type Activity Nr Safety Health
Accident 360589782
Violation Summary
Violations/Penalties Serious Willful Repeat Other Unclass Total
Initial Violations 1 1
Current Violations 1 1
Initial Penalty $420 $0 $0 $0 $0 $420
Current Penalty $238 $0 $0 $0 $0 $238
FTA Penalty $0 $0 $0 $0 $0 $0

Violation Items
# Citation ID Citaton Type Standard Cited Issuance Date Abatement Due Date Current Penalty Initial Penalty FTA Penalty Contest Latest Event Note
1. 01001 Serious 19260055 A 08/28/1985 08/31/1985 $238 $420 $0 09/27/1985 R - Review Commission  

Investigation Summary

Investigation Nr: 14448005
Event: 08/13/1985
EMPLOYEES INHALED CARBON MONOXIDE FROM GAS MASONRY SAW

A SUPERMARKET WAS TO BE TAKEN OVER BY NEW OWNERS ON AUGUST 12, 1985. ON AUG 11, 1985, THE STORE WAS CLOSED AT 6 PM. FOR AN INVENTORY AND SOME REMODELING. THE CASH REGISTERS WERE ALSO TO BE MOVED. A TRENCH, 22 INCHES WIDE AND 80 FEET LONG, HAD TO BE CUT IN THE CONCRETE FLOOR. THE NEW OWNER HIRED A MASONRY CONTRACTOR AND ELECTRICAL CONTRACTOR TO DO THE WORK. THEY ARRIVED AROUND 6:30 PM. THE MASONRY CONTRACTOR BROUGHT IN A GASOLINE-POWERED MASONRY SAW, 65 HORSEPOWER, CIMLINE BRAND. SAWING TOOK PLACE FOR TWO TO TWO AND A HALF HOURS. NO MECHANICAL VENTILATION OR EXHAUST PIPING WAS USED. AROUND 9:30 PM, THE ELECTRICIANS'S DAUGHTER, AN APPRENTICE ELECTRICIAN, PASSED OUT NEAR THE TRENCH. SHE HAD BEEN ASSEMBLING ELECTRICAL APPARATUS TO BE INSTALLED IN THE TRENCH. OTHER EMPLOYEES ALSO BECAME SICK AND WENT OUTSIDE. THE FIRE DEPARTMENT WAS CALLED TO VENTILATE THE STORE. WHEN THEY ARRIVED EIGHT EMPLOYEES WERE LYING ON THE PARKING LOT OUTSIDE THE STORE. VENTILATION WAS CONTINUED FOR ONE HALF HOUR. A CARBON MONOXIDE READING WAS TAKEN. THE LEVEL WAS STILL 200 PPM ABOUT TWENTY FEET FROM THE INCOMING FANS. AMBULANCES WERE CALLED AND A TOTAL OF 19 PEOPLE TAKEN TO THE HOSPITAL FOR CARBON MONOXIDE POISONING. THEY WERE VENTILATED, AND BLOOD TESTS TAKEN FOR SEVERAL HOURS. THE THE 19 EMPLOYEES WERE FROM A TOTAL OF 5 COMPANIES. ELECTRIC SAWS WERE AVAILABLE FOR USE IN THE STORE BUT WERE NOT USED.

Keywords: RESPIRATORY, INHALATION, SAW, TOXIC FUMES, CARBON MONOXIDE, VENTILATION

Investigated Inspection
# Inspection Age Sex Degree of Injury Nature of Injury Occupation
1 2904373 Non Hospitalized injury Asphyxia Managers and administrators, n.e.c
2 2904373 Non Hospitalized injury Asphyxia Management related occupations, n.e.c.
3 2904373 Non Hospitalized injury Asphyxia Electricians' apprentices
4 2904373 Non Hospitalized injury Asphyxia Construction laborers
5 2904373 Non Hospitalized injury Asphyxia Concrete and terrazzo finishers
6 2904373 Non Hospitalized injury Asphyxia Construction laborers
7 2904373 Non Hospitalized injury Asphyxia Supervisors, n.e.c.
8 2904373 Non Hospitalized injury Asphyxia Managers and administrators, n.e.c
9 2904373 Non Hospitalized injury Asphyxia Occupation not reported
10 2904373 Non Hospitalized injury Asphyxia Occupation not reported
11 2904373 Non Hospitalized injury Asphyxia Supervisors and proprietors, sales occupations
12 2904373 Non Hospitalized injury Asphyxia Receptionists
Back to Top

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.

Close