Powered by GoogleTranslate

Inspection Detail

Inspection: 2856565 - Rod-Buster Service Inc.

Inspection Information - Office: Department Of Labor, Licensing, And Regulation Division Of Labor And Industry Maryland Occupational Safety And Health

 

Inspection Nr: 2856565
Report ID: 0352440
Date Opened: 11/21/1985

Site Address:
Rod-Buster Service Inc.
7880 South Ritchie Highway
Glen Burnie, MD 21061

Mailing Address:
P. O. Box 206, White Marsh, MD 21162

Union Status: Union

SIC:1791

NAICS: 0 


Inspection Type: Accident

Scope: Partial

Advanced Notice: N

Ownership: Private

Safety/Health: Safety

Close Conference: 12/06/1985

Planning Guide: Safety-Construction

Emphasis:

Case Closed: 01/28/1986


Related Activity
Type Activity Nr Safety Health
Accident 360746267
Accident 360746275
Violation Summary
Violations/Penalties Serious Willful Repeat Other Unclass Total
Initial Violations 1 1
Current Violations 1 1
Initial Penalty $340 $0 $0 $0 $0 $340
Current Penalty $340 $0 $0 $0 $0 $340
FTA Penalty $0 $0 $0 $0 $0 $0

Violation Items
# Citation ID Citaton Type Standard Cited Issuance Date Abatement Due Date Current Penalty Initial Penalty FTA Penalty Contest Latest Event Note
1. 01001 Serious 19260550 A15 I 01/03/1986 01/05/1986 $340 $340 $0 -  

Investigation Summary

Investigation Nr: 14296180
Event: 11/19/1985
ELECTRIC SHOCK - CONTACT WITH OVERHEAD LINE THRU LOAD LINE

Some employees were using a Link-Belt truck crane (Model No. HC218, Serial No. 18HB151) to unload concrete reinforcement steel from a flatbed truck. The crane had a main boom that was 36.7 meters (120 feet) long with a 13.7-meter-long (45-foot-long) jib. One of the employees was standing on the bed of the truck, rigging the skids of material to be hoisted. He asked a coworker on the ground at the rear of the truck for another sling. The coworker handed him the choker-type sling that was attached to the load block. As the employee took the sling, the load line of the crane contacted a 7620-volt overhead power line located 9.6 meters (31.7 feet) above the ground. Both employees received electric shocks and sustained burns to their hands. They were hospitalized for their injuries.

Keywords: OVERHEAD POWER LINE, ELECTRICAL, E GI IA, ELECTRIC SHOCK, BURN, LOAD LINE, CRANE

Investigated Inspection
# Inspection Age Sex Degree of Injury Nature of Injury Occupation
1 2856565 Hospitalized injury Electric Shock Structural metal workers
Back to Top

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.