Powered by GoogleTranslate

Inspection Detail

Inspection: 2819480 - The Reimer Group Incorporated

Inspection Information - Office: Department Of Labor, Licensing, And Regulation Division Of Labor And Industry Maryland Occupational Safety And Health

 

Inspection Nr: 2819480
Report ID: 0352440
Date Opened: 08/22/1985

Site Address:
The Reimer Group Incorporated
9400 Block Pilgram Avenue
Laurel, MD 20707

Mailing Address:
3105 Helth Park Drive, Ellicott City, MD 21043

Union Status: NonUnion

SIC:8711

NAICS: 0 


Inspection Type: Accident

Scope: Partial

Advanced Notice: N

Ownership: Private

Safety/Health: Safety

Close Conference: 09/05/1985

Planning Guide: Safety-Construction

Emphasis:

Case Closed: 02/18/1986


Related Activity
Type Activity Nr Safety Health
Accident 360614366
Violation Summary
Violations/Penalties Serious Willful Repeat Other Unclass Total
Initial Violations 1 1
Current Violations 1 1
Initial Penalty $180 $0 $0 $0 $0 $180
Current Penalty $90 $0 $0 $0 $0 $90
FTA Penalty $0 $0 $0 $0 $0 $0

Violation Items
# Citation ID Citaton Type Standard Cited Issuance Date Abatement Due Date Current Penalty Initial Penalty FTA Penalty Contest Latest Event Note
1. 01001 Serious 19260021 B02 11/29/1985 11/30/1985 $90 $180 $0 12/13/1985 F - Formal Settlement  

Investigation Summary

Investigation Nr: 14295323
Event: 08/09/1985
ELECTRIC SHOCK - CONTACT WITH OVERHEAD LINE THRU ROD

SEVERAL EMPLOYEES WERE SURVEYING A WOODED AREA SO THAT THE AREA COULD BE GRADED FOR A ROAD. ONE EMPLOYEE (THE RODMAN) WAS HOLDING A 15-FOOT WOODEN ROD OVER HIS HEAD SO THAT THE INSTRUMENT OPERATOR COULD TAKE A READING OF THE GRADE. THE ROD HAD A METAL STRIP RUN ALONG ITS EDGE. THE RODMAN, WHO HAD BEEN EMPLOYED IN THIS FIELD FOR MORE THAN 2 YEARS, WAS STANDING UNDER 13-KILOVOLT OVERHEAD POWER LINES. WHEN THE EMPLOYEE RAISED THE ROD, IT CONTACTED THE POWER LINES. THE EMPLOYEE SUSTAINED ELECTRICAL BURNS TO HIS HANDS, FINGERS, AND FEET. NO PERSONAL PROTECTIVE EQUIPMENT WAS IN USE.

Keywords: BURN, SURVEYOR, OVERHEAD POWER LINE, ELECTRICAL, ELECTRIC SHOCK, E GI IC

Investigated Inspection
# Inspection Age Sex Degree of Injury Nature of Injury Occupation
1 2819480 Hospitalized injury Electric Shock Surveyors and mapping scientists
Back to Top

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.