Inspection Detail
Inspection: 2733889 - Indy Lighting Inc
Inspection Information - Office: Indiana
Site Address:
Indy Lighting Inc
8431 Castlewood Drive
Indianapolis, IN 46250
Mailing Address:
Po Box 50710, Indianapolis, IN 46250
Union Status: Union
SIC:3646
NAICS: 0
Inspection Type: Accident
Scope: Partial
Advanced Notice: N
Ownership: Private
Safety/Health: Safety
Close Conference: 06/27/1985
Planning Guide: Safety-Manufacturing
Emphasis:
Close Case:08/29/1985
Type | Activity Nr | Safety | Health |
---|---|---|---|
Accident | 360742589 |
Violations/Penalties | Serious | Willful | Repeat | Other | Unclass | Total |
---|---|---|---|---|---|---|
Initial Violations | 1 | 1 | ||||
Current Violations | 1 | 1 | ||||
Initial Penalty | $360 | $0 | $0 | $0 | $0 | $360 |
Current Penalty | $180 | $0 | $0 | $0 | $0 | $180 |
FTA Penalty | $0 | $0 | $0 | $0 | $0 | $0 |
# | Citation ID | Citaton Type | Standard | Issuance Date | Abatement Due Date | Current Penalty | Initial Penalty | FTA Penalty | Contest | Latest Event | Note |
---|---|---|---|---|---|---|---|---|---|---|---|
1. | 01001 | Serious | 19100303 G02 I | 07/03/1985 | 08/23/1985 | $180 | $360 | $0 | P - Petition to Mod Abatement |
Investigation Summary
An employee was assembling lighting fixtures. She pushed a 277-volt fixture tester back along her worktable. While she was pushing the tester, her hands contacted the two metal alligator clips on the test leads. She received a severe electric shock and a concussion.
Keywords:e gi v, electrical, test equipment, unguarded live parts, elec circ part--misc, electric shock, concussion
# | Inspection | Age | Sex | Degree | Nature | Occupation |
---|---|---|---|---|---|---|
1 | 2733889 | Non Hospitalized injury | Electric Shock | Laborers, except construction |