Investigation Nr: 14464226
Event: 08/20/1985
EXPOSURE TO PHOSGENE GAS

AT APPROXIMATELY 4 PM ON AUGUST 20, 1985, A PRESSURE BUILDUP IN THE REACTOR IN BUILDING NUMBER 14 CAUSED A SAFETY VALVE TO RUPTURE. THE REACTOR, WHICH CONTAINED BISPHENOL A (BPA) AND PHOSGENE GAS, VENTED THROUGHT THE SAFETY VALVE AND INTO LINES LEADING TO AN EMERGENCY SCRUBBER. THE PHOSGENE GAS LEAKED AROUND SOME LOOSE BOLTS IN A FLANGE ON THE LINE LEADING TO THE SCRUBBER. CONTRACTOR PERSONNEL WHO HAD WORKED ON THE LINE A FEW WEEKS AGO HAD NOT ADEQUATELY TIGHTENED THE FLANGE BOLTS. FIVE EMPLOYEES WERE EXPOSED TO THE LEAKING PHOSGENE GAS. EMPLOYEE #1 WAS ON HIS WAY TO BUILDING 45 TO QUIT WORK FOR THE DAY. HE WAS PROCEEDING ALONG THE EAST SIDE OF BUILDING 14 TO WARN OTHER EMPLOYEES TO EVACUATE THE AREA. EMPLOYEE #2 DROVE A VEHICLE THROUGH THE PHOSGENE CLOUD AND THEN ALONG THE EAST SIDE OF BUILDING 14 TO ANOTHER PART OF THE PLANT. EMPLOYEES #3 AND #4 WERE LOCATED ALONG THE EAST SIDE OF BUILDING 14, CLEANING A SEWER LINE. EMPLOYEE #5 WAS LOCATED AT THE SOUTH DOCK OF BUILDING 14, PUTTING HIS TOOLS AWAY AND QUITTING WORK FOR THE DAY. ALL FIVE EMPLOYEES WERE KEPT OVERNIGHT AT THE PLANT'S MEDICAL FACILITY AND OBSERVED BY THE PLANT'S PHYSICIAN. THE FIVE EMPLOYEES SUSTAINED NO INJURIES OR ILLNESSES AS A RESULT OF THEIR EXPOSURE TO PHOSGENE GAS.

Keywords: RESPIRATORY, TOXIC ATMOSPHERE, INHALATION, VALVE, PHOSGENE, RUPTURE, GAS LEAK

Investigated Inspection
# Inspection Age Sex Degree of Injury Nature of Injury Occupation
1 2701134 Hospitalized injury Poisoning(Systemic) Janitors and cleaners
2 2701134 Hospitalized injury Poisoning(Systemic) Janitors and cleaners
Back to Top

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.