Inspection Detail
Inspection: 2665065 - R R Donnelley & Sons Company
Inspection Information - Office: Indiana Department Of Labor
Site Address:
R R Donnelley & Sons Company
1009 Sloan St
Crawfordsville, IN 47933
Mailing Address:
, , 00000
Union Status: NonUnion
SIC:2732
NAICS: 0
Inspection Type: Accident
Scope: Partial
Advanced Notice: N
Ownership: Private
Safety/Health: Safety
Close Conference: 04/02/1986
Planning Guide: Safety-Manufacturing
Emphasis:
Case Closed: 12/31/1985
| Type | Activity Nr | Safety | Health |
|---|---|---|---|
| Accident | 360742381 |
| Violations/Penalties | Serious | Willful | Repeat | Other | Unclass | Total |
|---|---|---|---|---|---|---|
| Initial Violations | 1 | 1 | ||||
| Current Violations | 1 | 1 | ||||
| Initial Penalty | $630 | $0 | $0 | $0 | $0 | $630 |
| Current Penalty | $630 | $0 | $0 | $0 | $0 | $630 |
| FTA Penalty | $0 | $0 | $0 | $0 | $0 | $0 |
| # | Citation ID | Citaton Type | Standard Cited | Issuance Date | Abatement Due Date | Current Penalty | Initial Penalty | FTA Penalty | Contest | Latest Event | Note |
|---|---|---|---|---|---|---|---|---|---|---|---|
| 1. | 01001 | Serious | 19100303 G02 I | 02/10/1986 | 02/13/1986 | $630 | $630 | $0 | - |
Investigation Summary
A PRINTING MACHINE OPERATOR WAS HAVING PROBLEMS RESTARTING THE MOTOR ON A CSF-900 GILDER MACHINE. HE OPENED THE RIGHT DOOR ON THE 480-VOLT GILDER RELAY CONTROL PANEL. WITH THE LEFT DOOR CLOSED AND THE DISCONNECT HANDLE IN THE "ON" POSITION, HE TRIED TO RESET THE RELAYS. WHEN HE COULD NOT FIND THE TRIPPED RELAY ON THE RIGHT SIDE, HE REACHED BEHIND THE CLOSED LEFT DOOR. HE MADE CONTACT WITH LIVE PARTS ENERGIZED AT 480 VOLTS AND WAS ELECTROCUTED.
Keywords: ELECTRIC MOTOR, ELECTRICAL, E GI VI, ELECTROCUTED, PANELBOARD, ELECTRICAL WORK
| # | Inspection | Age | Sex | Degree of Injury | Nature of Injury | Occupation |
|---|---|---|---|---|---|---|
| 1 | 2665065 | Fatality | Electric Shock | Miscellaneous printing machine operators |
Translate