Inspection Detail
Inspection: 2579209 - Anderson Passarelli & Associates
Inspection Information - Office: Arizona Division Of Occupational Safety And Health (Adosh)
Site Address:
Anderson Passarelli & Associates
1 Mi E Of Vail Rd Adjacent To Rr Track
Vail, AZ 85641
Mailing Address:
288 N Church Ave, Tucson, AZ 85701
Union Status: NonUnion
SIC:8711
NAICS: 0
Inspection Type: Accident
Scope: Partial
Advanced Notice: N
Ownership: Private
Safety/Health: Safety
Close Conference: 10/16/1986
Planning Guide: Safety-Construction
Emphasis:
Case Closed: 12/10/1986
Type | Activity Nr | Safety | Health |
---|---|---|---|
Accident | 360104061 |
Investigation Summary
A SURVEYING TECHNICIAN FOR AN ENGINEERING FIRM WAS SURVEYING A SITE FOR AERIAL PHOTOGRAPHY. HE AND ANOTHER EMPLOYEE WERE LAYING OUT A PLASTIC PANEL TO FORM A CROSS FOR THE CENTER SECTION MARKER. THIS MARKER WAS LOCATED ON A RAILWAY RIGHT-OF-WAY BENEATH SOME OVERHEAD RAILWAY POWER LINES. (THE POWER LINES WERE USED TO CHARGE STORAGE BATTERIES THAT SUPPLIED POWER TO THE RAIL SIGNALLING SYSTEM.) THE 240-VOLT POWER LINES WERE ONLY 4 FEET ABOVE THE GROUND AT THE TOP OF A HILL WHERE THE MARKER WAS TO BE PLACED. THE SURVEYOR WAS IN A KNEELING POSITION UNDER THE POWER LINES; AND, WHEN HE STOOD UP, HE CONTACTED THE LINES AND WAS ELECTROCUTED.
Keywords: E GI III, OVERHEAD POWER LINE, ELECTRICAL, ELECTROCUTED, UNGUARDED LIVE PARTS, UNTRAINED
# | Inspection | Age | Sex | Degree of Injury | Nature of Injury | Occupation |
---|---|---|---|---|---|---|
1 | 2579209 | Fatality | Electric Shock | Surveying and mapping technicians |