Powered by GoogleTranslate

Inspection Detail

Inspection: 2578060 - Rowley Pipe Lines, Inc.

Inspection Information - Office: Arizona Division Of Occupational Safety And Health (Adosh)

 

Inspection Nr: 2578060
Report ID: 0950411
Date Opened: 08/27/1986

Site Address:
Rowley Pipe Lines, Inc.
1920 So. Lewis
Mesa, AZ 85202

Mailing Address:
611 No Golden Key St., Gilbert, AZ 85234

Union Status: NonUnion

SIC:1623

NAICS: 0 


Inspection Type: Accident

Scope: Complete

Advanced Notice: N

Ownership: Private

Safety/Health: Safety

Close Conference: 09/03/1986

Planning Guide: Safety-Construction

Emphasis:

Case Closed: 10/14/1986


Related Activity
Type Activity Nr Safety Health
Accident 360104376
Violation Summary
Violations/Penalties Serious Willful Repeat Other Unclass Total
Initial Violations 1 1 2
Current Violations
Initial Penalty $640 $0 $0 $0 $0 $640
Current Penalty $0 $0 $0 $0 $0 $0
FTA Penalty $0 $0 $0 $0 $0 $0

Violation Items
# Citation ID Citaton Type Standard Cited Issuance Date Abatement Due Date Current Penalty Initial Penalty FTA Penalty Contest Latest Event Note
1. 01001 Serious 230403 A 09/17/1986 10/06/1986 $640 $640 $0 I - Informal Settlement Citation has been deleted.
2. 02001 Other 19260028 A 09/17/1986 09/20/1986 $0 $0 $0 I - Informal Settlement Citation has been deleted.

Investigation Summary

Investigation Nr: 14264196
Event: 08/27/1986
BURN - SHOVEL CONTACT WITH UNDERGROUND POWER LINE

THREE EMPLOYEES OF A PIPE LAYING COMPANY HAD EXCAVATED A TRENCH 3.5 FEET DEEP, 3 FEET WIDE, AND 15 FEET LONG. THE TRENCH WAS TO CARRY A HIGH PRESSURE WATER LINE UNDER AN EXISTING UNDERGROUND POWER LINE. THE EMPLOYEES HAD USED A BACK HOE TO EXCAVATE THE AREA TO WITHIN 12 INCHES OF A 3-INCH-DIAMETER TELEPHONE CONDUIT. THE EMPLOYEES THEN BEGAN PROBING FOR THE POWER LINE USING A 6-FOOT-LONG ALL-METAL SHOVEL (CALLED A "SHARPSHOOTER"). DURING THIS OPERATION, THE SHOVEL CONTACTED THE UNDERGROUND POWER LINE AND CAUSED AN ELECTRICAL FAULT. THE RESULTING ARC BURNED TWO OF THE EMPLOYEES--ONE ON HIS FACE, THE OTHER ON BOTH ARMS. BOTH EMPLOYEES WERE TREATED AND RELEASED AT A LOCAL HOSPITAL.

Keywords: BURN, CLOTHING, ELECTRIC ARC, ELECTRICAL, TRENCH, E C, ELECTRICAL FAULT, SHOVEL, UNDRGRD POWER LINE

Investigated Inspection
# Inspection Age Sex Degree of Injury Nature of Injury Occupation
1 2578060 Non Hospitalized injury Burn/Scald(Heat) Construction laborers
2 2578060 Non Hospitalized injury Burn/Scald(Heat) Construction laborers
Back to Top

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.

Close