Powered by GoogleTranslate

Inspection Detail

Inspection: 2517670 - Goentzel Builders

Inspection Information - Office: Alaska Department Of Labor Osh Enforcement

 

Inspection Nr: 2517670
Report ID: 1050210
Date Opened: 07/18/1985

Site Address:
Goentzel Builders
431 Business Blvd
Eagle River, AK 99577

Mailing Address:
2418 East 86th Court, Anch, AK 99507

Union Status: NonUnion

SIC:1542

NAICS: 0 


Inspection Type: Accident

Scope: Complete

Advanced Notice: N

Ownership: Private

Safety/Health: Safety

Close Conference: 07/23/1985

Planning Guide: Safety-Construction

Emphasis:

Case Closed: 09/27/1985


Related Activity
Type Activity Nr Safety Health
Accident 360733869
Violation Summary
Violations/Penalties Serious Willful Repeat Other Unclass Total
Initial Violations 2 1 1 4
Current Violations 2 1 1 4
Initial Penalty $1,260 $0 $720 $0 $0 $1,980
Current Penalty $1,080 $0 $720 $0 $0 $1,800
FTA Penalty $0 $0 $0 $0 $0 $0

Violation Items
# Citation ID Citaton Type Standard Cited Issuance Date Abatement Due Date Current Penalty Initial Penalty FTA Penalty Contest Latest Event Note
1. 01001 Serious 50140 A01 O 08/01/1985 08/04/1985 $720 $720 $0 -  
2. 02001 Repeat 50030 B2A I 08/01/1985 08/27/1985 $720 $720 $0 -  
3. 03001A Serious 50140 A1G II 08/01/1985 08/09/1985 $360 $540 $0 I - Informal Settlement  
4. 03001B Serious 50140 A01 F 08/01/1985 08/27/1985 $0 $0 $0 -  
5. 03001C Serious 50140 A2D II 08/01/1985 08/12/1985 $0 $0 $0 I - Informal Settlement Citation has been deleted.
6. 04001 Other 50140 A1M I 08/01/1985 08/04/1985 $0 $0 $0 -  

Investigation Summary

Investigation Nr: 14304349
Event: 07/18/1985
ELECTRIC SHOCK - CONTACT WITH OVERHEAD LINE THRU CRANE

A MOBILE CRANE WAS BEING USED TO UNLOAD METAL BEAMS FROM A LOWBOY TRACTOR TRAILER. THE CRANE WAS SET UP DIRECTLY BELOW AN OVERHEAD POWER LINE. THE METAL BEAMS WERE BEING UNLOADED ON ONE SIDE OF THE LINES AND SWUNG UNDER THEM TO THE OTHER SIDE. WHEN THE CRANE OPERATOR HAD UNLOADED ABOUT HALF THE LOAD, HE EXTENDED THE BOOM TO GAIN REACH. THE BOOM WAS SWUNG INTO ONE OF THE POWER LINES. TWO EMPLOYEES WERE HOSPITALIZED FOR ELECTRIC SHOCK.

Keywords: OVERHEAD POWER LINE, ELECTRICAL, E GI IA, ELECTRIC SHOCK, BOOM, CRANE BOOM, CRANE

Investigated Inspection
# Inspection Age Sex Degree of Injury Nature of Injury Occupation
1 2517670 Hospitalized injury Electric Shock Supervisors; carpenters and related workers
2 2517670 Hospitalized injury Electric Shock Truck drivers, heavy
Back to Top

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.

Close