Inspection Detail
Inspection: 2468809 - Chaparral Steel
Inspection Information - Office: Dallas Area Office
Site Address:
Chaparral Steel
300 Ward Rd
Midlothian, TX 76065
Mailing Address:
, , 00000
Union Status: NonUnion
SIC:3312
NAICS: 0
Inspection Type: Accident
Scope: Partial
Advanced Notice: N
Ownership: Private
Safety/Health: Safety
Close Conference: 07/15/1985
Planning Guide: Safety-Manufacturing
Emphasis:
Case Closed: 07/15/1985
Type | Activity Nr | Safety | Health |
---|---|---|---|
Accident | 360644280 |
Investigation Summary
EMPLOYEE #1 WORKED ON A PLATFORM AS A POURER IN A STEEL FOUNDRY. HIS JOB WAS TO CONTROL THE LEVEL OF MOLTEN METAL IN A TUNDISH SEVERAL FEET BELOW. HE WAS ASPHYXIATED WHEN HE DONNED A 3 M BRAND WHITECAP W-5002 SUPPLIED AIR RESPIRATOR THAT HAD BEEN CONNECTED TO NITROGEN RATHER THAN COMPRESSED AIR. AN UNMARKED PLANT NITROGEN LINE HAD BEEN BROUGHT UP TO THE PLATFORM FOR USE BY THE RESPIRATOR WEARER. NO OTHER GASES WERE USED ON THE PLATFORM.
Keywords: RESPIRATORY, AIR LINE RESPIRATOR, ASPHYXIATED, MARKING, NITROGEN, FOUNDRY, RESPIRATOR
# | Inspection | Age | Sex | Degree of Injury | Nature of Injury | Occupation |
---|---|---|---|---|---|---|
1 | 2468809 | Occupation Not Listed |