Inspection Detail
Inspection: 2461002 - Clearwater Concrete Industries, Inc.
Inspection Information - Office: Tampa Area Office
Site Address:
Clearwater Concrete Industries, Inc.
1700 N. Hercules
Clearwater, FL 33575
Mailing Address:
, , 00000
Union Status: NonUnion
SIC:3271
NAICS: 0
Inspection Type: Accident
Scope: Partial
Advanced Notice: N
Ownership: Private
Safety/Health: Safety
Close Conference: 09/10/1985
Planning Guide: Safety-Manufacturing
Emphasis:
Case Closed: 09/11/1985
Type | Activity Nr | Safety | Health |
---|---|---|---|
Accident | 360710560 |
Investigation Summary
A TRUCK DRIVER WAS UNLOADING A PALLET OF BRICKS WITH A JIFFY LIFT HYDRAULIC BOOM MOUNTED ON A BOOM TRUCK. HE WAS POSITIONING THE BOOM TO PLACE THE BRICKS BETWEEN TWO HOUSE TRAILERS, AND THE BOOM CONTACTED A 7200-VOLT OVERHEAD POWER LINE THAT RAN BETWEEN THE TRAILERS. THE TRUCK DRIVER WAS ELECTROCUTED.
Keywords: BOOM TRUCK, OVERHEAD POWER LINE, ELECTRICAL, BOOM, ELECTROCUTED, E GI IA
# | Inspection | Age | Sex | Degree of Injury | Nature of Injury | Occupation |
---|---|---|---|---|---|---|
1 | 2461002 | Fatality | Electric Shock | Truck drivers, heavy |