Powered by GoogleTranslate

Inspection Detail

Inspection: 2449775 - Southwest Trinity Constructors Inc

Inspection Information - Office: Oklahoma City Area Office

 

Inspection Nr: 2449775
Report ID: 0627700
Date Opened: 08/28/1985

Site Address:
Southwest Trinity Constructors Inc
4 1/2 Miles West Of 73199 North Hwy 32 Appox 1 1/2
Marrietta, OK 80134

Mailing Address:
Po Box 1349, Panker, CO 80134

Union Status: NonUnion

SIC:1623

NAICS: 0 


Inspection Type: Accident

Scope: Partial

Advanced Notice: N

Ownership: Private

Safety/Health: Safety

Close Conference: 08/29/1985

Planning Guide: Safety-Construction

Emphasis:

Case Closed: 11/07/1985


Related Activity
Type Activity Nr Safety Health
Accident 360547988
Violation Summary
Violations/Penalties Serious Willful Repeat Other Unclass Total
Initial Violations 1 1
Current Violations 1 1
Initial Penalty $640 $0 $0 $0 $0 $640
Current Penalty $640 $0 $0 $0 $0 $640
FTA Penalty $0 $0 $0 $0 $0 $0

Violation Items
# Citation ID Citaton Type Standard Cited Issuance Date Abatement Due Date Current Penalty Initial Penalty FTA Penalty Contest Latest Event Note
1. 01001A Serious 19260602 A02 I 09/27/1985 10/09/1985 $640 $640 $0 -  
2. 01001B Serious 19260602 A06 09/27/1985 09/30/1985 $0 $0 $0 -  

Investigation Summary

Investigation Nr: 14494744
Event: 08/20/1985
FRONT END LOADER OVERTURNED, CRUSHING OPERATOR

EMPLOYEE #1, PERFORMING HIS REGULARLY ASSIGNED TASK AS AN EQUIPMENT OPERATOR, WAS PULLING A SOCK LINE BETWEEN TWO POWER POLES. TO DO THIS, HE CHOSE TO USE THE FRONT END LOADER LOCATED ON SITE. HE WAS MOVING UPHILL TOWARD THE STRUCTURE TO WHICH THE LINES WERE TO BE CONNECTED WHEN THE DIESEL ENGINE ON THE LOADER DIED. THIS CAUSED THE LOADER TO LOOSE ITS BRAKES, BECAUSE THE REGULAR BRAKES WERE POWER ASSISTED AND IT HAD NO EMERGENCY BRAKE. THE LOADER COASTED BACKWARDS DOWN THE HILL, ONLY MARGINALLY UNDER CONTROL OF THE OPERATOR. AFTER RUNNING INTO A DITCH AT THE BOTTOM OF THE HILL, THE LOADER OVERTURNED, CRUSHING THE OPERATOR, WHO HAD BEEN THROWN OUT OF THE DRIVER'S SEAT. THE FRONT END LOADER WAS NOT EQUIPPED WITH A ROPS OR SEAT BELT. EMPLOYEE #2, WHO WAS INVOLVED IN THE EFFORT TO TO RESCUE EMPLOYEE #1, SUFFERED FROM HEAT EXHAUSTION AND WAS HOSPITALIZED.

Keywords: FRONT END LOADER, BRAKE, ROPS, SEAT BELT, HEAT EXHAUSTION, LOST CONTROL, OVERTURN

Investigated Inspection
# Inspection Age Sex Degree of Injury Nature of Injury Occupation
1 2449775 Fatality Concussion Occupation not reported
2 2449775 Hospitalized injury Heat Exhaustion Occupation not reported
Back to Top

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.