Inspection Detail
Inspection: 2440360 - Texaco, Inc.
Inspection Information - Office: Dallas Area Office
Site Address:
Texaco, Inc.
4 Miles E. Of Streetman, Tx., Off Fm 416
Streetman, TX 75859
Mailing Address:
, , 00000
Union Status: NonUnion
SIC:2819
NAICS: 0
Inspection Type: Accident
Scope: Partial
Advanced Notice: N
Ownership: Private
Safety/Health: Health
Close Conference: 03/10/1988
Emphasis:
Case Closed: 03/11/1988
| Type | Activity Nr | Safety | Health |
|---|---|---|---|
| Accident | 360694046 |
Investigation Summary
EMPLOYEE #1 WAS MAKING HIS ROUNDS AT THE PLANT WHEN HE INEXPLICABLY OPENED A BLEEDER VALVE AT THE STRIPPER REFLUX ACCUMULATOR. THE OPENED VALVE ALLOWED TOXIC HYDROGEN SULFIDE TO ESCAPE. THE EMPLOYEE BREATHED THE HYDROGEN SULFIDE AND WAS KILLED. NO ONE KNOWS WHY THE EMPLOYEE WOULD HAVE OPENED THE BLEEDER VALVE.
Keywords: RESPIRATORY, HYDROGEN SULFIDE, WORK RULES, INHALATION, VALVE, TOXIC FUMES
| # | Inspection | Age | Sex | Degree of Injury | Nature of Injury | Occupation |
|---|---|---|---|---|---|---|
| 1 | 2440360 | Fatality | Asphyxia | Occupation not reported |
Translate