Powered by GoogleTranslate

Inspection Detail

Inspection: 2439511 - Trumball, A Division Of Owens-Corning Fiberglas

Inspection Information - Office: Oklahoma City Area Office

 

Inspection Nr: 2439511
Report ID: 0627700
Date Opened: 09/22/1987

Site Address:
Trumball, A Division Of Owens-Corning Fiberglas
3400 Ne 4th
Oklahoma City, OK 73117

Mailing Address:
, , 00000

Union Status: NonUnion

SIC:2952

NAICS: 0 


Inspection Type: Referral

Scope: Partial

Advanced Notice: N

Ownership: Private

Safety/Health: Safety

Close Conference: 09/25/1988

Planning Guide: Safety-Manufacturing

Emphasis:

Case Closed: 11/14/1988


Related Activity
Type Activity Nr Safety Health
Referral 900543034 Yes
Violation Summary
Violations/Penalties Serious Willful Repeat Other Unclass Total
Initial Violations 2 6 8
Current Violations 2 6 8
Initial Penalty $1,600 $0 $0 $0 $0 $1,600
Current Penalty $800 $0 $0 $0 $0 $800
FTA Penalty $0 $0 $0 $0 $0 $0

Violation Items
# Citation ID Citaton Type Standard Cited Issuance Date Abatement Due Date Current Penalty Initial Penalty FTA Penalty Contest Latest Event Note
1. 01001 Serious 5A0001 02/10/1988 03/07/1988 $0 $800 $0 02/29/1988 F - Formal Settlement  
2. 01002 Serious 19100157 G02 02/10/1988 02/29/1988 $800 $800 $0 02/29/1988 -  
3. 02001 Other 19030002 A01 02/10/1988 02/17/1988 $0 $0 $0 02/29/1988 -  
4. 02002 Other 19040002 B02 02/10/1988 02/17/1988 $0 $0 $0 02/29/1988 -  
5. 02003 Other 19040007 A 02/10/1988 02/17/1988 $0 $0 $0 02/29/1988 -  
6. 02004 Other 19100157 C04 02/10/1988 02/17/1988 $0 $0 $0 02/29/1988 -  
7. 02005 Other 19100157 E03 02/10/1988 02/17/1988 $0 $0 $0 02/29/1988 -  
8. 02006 Other 19100157 F16 02/10/1988 02/17/1988 $0 $0 $0 02/29/1988 -  

Investigation Summary

Investigation Nr: 14495428
Event: 09/21/1987
THREE EMPLOYEES BURNED IN EXPLOSION AT ASPHALT PLANT

ON SEPTEMBER 21, 1987, THREE EMPLOYEES WERE FIGHTING A FIRE IN THE PREHEATER BOX AT AN ASPHALT MANUFACTURING PLANT. THEY WERE NOT ABLE TO EXTINGUISH THE FIRE WITH HAND HELD FIRE EXTINGUISHERS AND HAD BACKED AWAY FROM THE FIRE AREA ABOUT 58 FEET TO THE WEST. THEY HAD BEEN STANDING IN THAT AREA FOR ABOUT 5 MINUTES WHEN THEY HEARD A HISSING NOISE AND REALIZED SOMETHING WAS GOING TO EXPLODE. THEY TURNED AND WERE RUNNING AWAY WHEN HE ASPHALT PUMP EXPLODED. A FIRE PLUME ENGULFED THE THREE EMPLOYEES FROM THE REAR. THEY SUSTAINED SECOND AND THIRD DEGREE BURNS ON THEIR BACKS AND THE BACK SIDE OF THEIR LEGS, ARMS AND HEAD (OVER 50% OF THEIR BODIES).

Keywords: BURN, HEAD, FIRE EXTINGUISHER, FIRE, BACK, EXPLOSION, ARM, ASPHALT, LEG

Investigated Inspection
# Inspection Age Sex Degree of Injury Nature of Injury Occupation
1 2439511 Hospitalized injury Burn/Scald(Heat) Occupation not reported
2 2439511 Hospitalized injury Burn/Scald(Heat) Occupation not reported
3 2439511 Hospitalized injury Burn/Scald(Heat) Occupation not reported
Back to Top

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.