Inspection Detail
Inspection: 2298222 - Holley'S Lease Service Inc
Inspection Information - Office: Corpus Christi Area Office
Site Address:
Holley'S Lease Service Inc
Approx 2 1/2 Mi S W Off Fm 318
Hallettsville, TX 77964
Mailing Address:
P O Box 501, Hallettsville, TX 77964
Union Status: NonUnion
SIC:1389
NAICS: 0
Inspection Type: Accident
Scope: Complete
Advanced Notice: Y
Ownership: Private
Safety/Health: Safety
Close Conference: 11/27/1985
Emphasis: L:Oilgas
Case Closed: 04/16/1986
| Type | Activity Nr | Safety | Health |
|---|---|---|---|
| Accident | 360510994 |
| Violations/Penalties | Serious | Willful | Repeat | Other | Unclass | Total |
|---|---|---|---|---|---|---|
| Initial Violations | 1 | 2 | 3 | |||
| Current Violations | 1 | 2 | 3 | |||
| Initial Penalty | $280 | $0 | $0 | $0 | $0 | $280 |
| Current Penalty | $280 | $0 | $0 | $0 | $0 | $280 |
| FTA Penalty | $0 | $0 | $0 | $0 | $0 | $0 |
| # | Citation ID | Citaton Type | Standard Cited | Issuance Date | Abatement Due Date | Current Penalty | Initial Penalty | FTA Penalty | Contest | Latest Event | Note |
|---|---|---|---|---|---|---|---|---|---|---|---|
| 1. | 01001 | Serious | 19100180 J01 I | 12/13/1985 | 12/17/1985 | $280 | $280 | $0 | - | ||
| 2. | 02001 | Other | 19030002 A01 | 12/13/1985 | 12/17/1985 | $0 | $0 | $0 | - | ||
| 3. | 02002 | Other | 19040002 A | 12/13/1985 | 12/17/1985 | $0 | $0 | $0 | - |
Investigation Summary
A CRANE WAS BEING OPERATED NEAR A 7200-VOLT OVERHEAD POWER LINE. THE CRANE BOOM CONTACTED THE OVERHEAD LINE. ONE EMPLOYEE WAS ELECTROCUTED; ANOTHER WAS HOSPITALIZED FOR HIS INJURIES.
Keywords: OVERHEAD POWER LINE, ELECTRICAL, BOOM, CRANE BOOM, ELECTROCUTED, E C, ELECTRIC SHOCK, CRANE
| # | Inspection | Age | Sex | Degree of Injury | Nature of Injury | Occupation |
|---|---|---|---|---|---|---|
| 1 | 2298222 | Fatality | Electric Shock | Occupation not reported | ||
| 2 | 2298222 | Hospitalized injury | Electric Shock | Occupation not reported |
Translate