Inspection Detail
Inspection: 2240513 - Commonwealth Edison Co Station 20
Inspection Information - Office: Chicago South Area Office
Site Address:
Commonwealth Edison Co Station 20
1 1/2 Mile S Of Braidwood Il
Braidwood, IL 60408
Mailing Address:
Rr 1 Box 81, Braceville, IL 60407
Union Status: Union
SIC:1629
NAICS: 0
Inspection Type: Accident
Scope: Partial
Advanced Notice: N
Ownership: Private
Safety/Health: Safety
Close Conference: 03/01/1985
Planning Guide: Safety-Construction
Emphasis:
Case Closed: 11/26/1985
Type | Activity Nr | Safety | Health |
---|---|---|---|
Accident | 360649107 |
Investigation Summary
The employee entered a 24-in pipe to grind a bad weld. Oxygen was piped into the space to prevent asphyxiation. The atmosphere in the pipe became oxygen enriched and heat generated from the grinding caused the atmosphere to ignite. The employee scrambled out of the pipe. He sustained severe burns and died.
Keywords: BURN, OXYGEN, CONFINED SPACE, GRINDING WHEEL
# | Inspection | Age | Sex | Degree of Injury | Nature of Injury | Occupation |
---|---|---|---|---|---|---|
1 | 2240513 | Occupation Not Listed |