Powered by GoogleTranslate

Inspection Detail

Inspection: 2185981 - Mehaffy Construction Co Inc

Inspection Information - Office: Little Rock Area Office

 

Inspection Nr: 2185981
Report ID: 0627100
Date Opened: 09/19/1985

Site Address:
Mehaffy Construction Co Inc
3mi E On Hwy 114
Calmer, AR 71665

Mailing Address:
Po Box 339, No Little Rock, AR 72115

Union Status: NonUnion

SIC:1622

NAICS: 0 


Inspection Type: Accident

Scope: Complete

Advanced Notice: N

Ownership: Private

Safety/Health: Safety

Close Conference: 09/23/1985

Planning Guide: Safety-Construction

Emphasis:

Case Closed: 11/19/1985


Related Activity
Type Activity Nr Safety Health
Accident 360688964
Violation Summary
Violations/Penalties Serious Willful Repeat Other Unclass Total
Initial Violations 3 4 7
Current Violations 3 4 7
Initial Penalty $420 $0 $0 $0 $0 $420
Current Penalty $210 $0 $0 $0 $0 $210
FTA Penalty $0 $0 $0 $0 $0 $0

Violation Items
# Citation ID Citaton Type Standard Cited Issuance Date Abatement Due Date Current Penalty Initial Penalty FTA Penalty Contest Latest Event Note
1. 01001 Serious 19260303 C03 10/17/1985 10/28/1985 $45 $90 $0 I - Informal Settlement  
2. 01002A Serious 19260400 H01 10/17/1985 11/12/1985 $60 $120 $0 I - Informal Settlement  
3. 01002B Serious 19260401 C 10/17/1985 11/12/1985 $0 $0 $0 -  
4. 01003A Serious 19260550 A15 I 10/17/1985 10/20/1985 $105 $210 $0 I - Informal Settlement  
5. 01003B Serious 19260550 A15 IV 10/17/1985 10/22/1985 $0 $0 $0 -  
6. 02001 Other 19260350 A04 10/17/1985 10/28/1985 $0 $0 $0 -  
7. 02002 Other 19260350 H 10/17/1985 10/28/1985 $0 $0 $0 -  
8. 02003 Other 19260550 A05 10/17/1985 10/20/1985 $0 $0 $0 -  
9. 02004 Other 19260550 A14 I 10/17/1985 10/20/1985 $0 $0 $0 -  

Investigation Summary

Investigation Nr: 14496335
Event: 09/18/1985
ELECTRIC SHOCK - CONTACT WITH OVERHEAD LINE THRU LOAD LINE

A truck crane operator raised a load (an 11.9-meter-long scaffold board) from a flat bed truck. After the load cleared the flat bed truck, the operator swung the boom clockwise and lowered the load so that three employees could guide it into position. One of the employees lost his grip, and the load, which was attached to the load line with a 6.1-meter-long chain sling, rotated toward a 13.2-kilovolt overhead power line. The three employees guiding the load released it, but the scaffold board contacted the left forearm of one of the employees while the load line was in contact with the power line. This employee was electrocuted. The crane operator had raised the boom and had rotated it toward the power line. In order to maintain the required 3-meter minimum approach distance from the power line with the crane located where it was, the boom angle would have had to have been about 80 degrees, which was 2 degrees beyond its rating.

Keywords: OVERHEAD POWER LINE, ELECTRICAL, ELECTROCUTED, E GI IA, LOAD LINE, CRANE

Investigated Inspection
# Inspection Age Sex Degree of Injury Nature of Injury Occupation
1 2185981 Fatality Electric Shock Occupation not reported
Back to Top

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.