Powered by GoogleTranslate

Inspection Detail

Inspection: 2175479 - Marine Maintenance Industries

Inspection Information - Office: Houston North Area Office

 

Inspection Nr: 2175479
Report ID: 0626600
Date Opened: 01/16/1986

Site Address:
Marine Maintenance Industries
Todd Shipbuilding Pelican Island
Galveston, TX 77550

Mailing Address:
1802 Mechanic, Galveston, TX 77550

Union Status: Union

SIC:4491

NAICS: 0 


Inspection Type: Accident

Scope: Partial

Advanced Notice: N

Ownership: Private

Safety/Health: Safety

Close Conference: 01/16/1986

Planning Guide: Safety-Maritime

Emphasis:

Case Closed: 10/21/1986


Related Activity
Type Activity Nr Safety Health
Accident 360706626
Violation Summary
Violations/Penalties Serious Willful Repeat Other Unclass Total
Initial Violations 5 5
Current Violations 5 5
Initial Penalty $2,030 $0 $0 $0 $0 $2,030
Current Penalty $1,015 $0 $0 $0 $0 $1,015
FTA Penalty $0 $0 $0 $0 $0 $0

Violation Items
# Citation ID Citaton Type Standard Cited Issuance Date Abatement Due Date Current Penalty Initial Penalty FTA Penalty Contest Latest Event Note
1. 01001A Serious 19150012 A01 02/27/1986 03/02/1986 $166 $420 $0 05/12/1986 F - Formal Settlement  
2. 01001B Serious 19150013 A03 02/27/1986 03/02/1986 $0 $0 $0 05/12/1986 F - Formal Settlement  
3. 01002 Serious 19150013 A02 02/27/1986 03/02/1986 $166 $420 $0 05/12/1986 F - Formal Settlement  
4. 01003 Serious 19150013 F 02/27/1986 03/02/1986 $166 $420 $0 05/12/1986 F - Formal Settlement  
5. 01004 Serious 19150052 B02 02/27/1986 03/02/1986 $167 $420 $0 05/12/1986 F - Formal Settlement  
6. 01005 Serious 19150152 C02 I 02/27/1986 03/02/1986 $350 $350 $0 -  

Investigation Summary

Investigation Nr: 14498562
Event: 01/16/1986
FLAMMABLE SOLVENT USED IN CLEANING SHIP HOLD IGNITED

THE EMPLOYEES WERE CLEANING BUNKERS IN THE NUMBER FOUR DOUBLE-BOTTOM HOLD. THEY WERE SPRAYING "GYRO CHEM" FOR USE AS A SOLVENT. OPEN LIGHTS (NOT APPROVED FOR A HAZARDOUS LOCATION) WERE STRUNG THROUGH THE ESCAPE MATCH FROM THE MAIN DECK TO THE DOUBLE BOTTOM. SOLVENT AND RESIDUE WERE BEING REMOVED BY BUCKETS UP THROUGH THE ESCAPE HATCH. A FIRE STARTED IN THE "TWEEN DECK", TRAPPING 13 EMPLOYEES IN THE LOWER HOLD AND TWEEN DECKS. PONTOONS (ROLLING HATCH COVERS) WERE ON THE MAIN DECK. THE FLAMES SHOT UP THROUGH THE ESCAPE HATCH, MAKING ESCAPE IMPOSSIBLE.

Keywords: CONFINED SPACE, FLAMMABLE VAPORS, WORK RULES, CLEANING, FIRE, EXPLOSION, SHIP, CHEMICAL

Investigated Inspection
# Inspection Age Sex Degree of Injury Nature of Injury Occupation
1 2175479 Hospitalized injury Asphyxia Occupation not reported
2 2175479 Hospitalized injury Asphyxia Occupation not reported
3 2175479 Hospitalized injury Burn/Scald(Heat) Occupation not reported
4 2175479 Hospitalized injury Burn/Scald(Heat) Occupation not reported
5 2175479 Hospitalized injury Burn/Scald(Heat) Occupation not reported
6 2175479 Hospitalized injury Burn/Scald(Heat) Occupation not reported
7 2175479 Hospitalized injury Burn/Scald(Heat) Occupation not reported
8 2175479 Hospitalized injury Burn/Scald(Heat) Occupation not reported
9 2175479 Hospitalized injury Asphyxia Occupation not reported
10 2175479 Hospitalized injury Asphyxia Occupation not reported
11 2175479 Hospitalized injury Asphyxia Occupation not reported
12 2175479 Hospitalized injury Asphyxia Occupation not reported
13 2175479 Hospitalized injury Asphyxia Occupation not reported
14 2175479 Hospitalized injury Asphyxia Occupation not reported
15 2175479 Hospitalized injury Asphyxia Occupation not reported
16 2175479 Hospitalized injury Asphyxia Occupation not reported
Back to Top

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.