Powered by GoogleTranslate

Inspection Detail

Inspection: 2173995 - Peachtree Doors, Inc.

Inspection Information - Office: Atlanta East Area Office

 

Inspection Nr: 2173995
Report ID: 0418100
Date Opened: 06/04/1985

Site Address:
Peachtree Doors, Inc.
3151 Peachtree Industrial Blvd.
Norcross, GA 30091

Mailing Address:
P. O. Box 5700, Norcross, GA 30091

Union Status: NonUnion

SIC:3231

NAICS: 0 


Inspection Type: Referral

Scope: Partial

Advanced Notice: N

Ownership: Private

Safety/Health: Safety

Close Conference: 06/19/1985

Planning Guide: Safety-Manufacturing

Emphasis:

Case Closed: 07/22/1985


Related Activity
Type Activity Nr Safety Health
Referral 900966003 Yes
Violation Summary
Violations/Penalties Serious Willful Repeat Other Unclass Total
Initial Violations 3 1 4
Current Violations 3 1 4
Initial Penalty $2,070 $0 $0 $0 $0 $2,070
Current Penalty $2,070 $0 $0 $0 $0 $2,070
FTA Penalty $0 $0 $0 $0 $0 $0

Violation Items
# Citation ID Citaton Type Standard Cited Issuance Date Abatement Due Date Current Penalty Initial Penalty FTA Penalty Contest Latest Event Note
1. 01001 Serious 19100106 E03 VA 06/25/1985 07/29/1985 $720 $720 $0 -  
2. 01002 Serious 19100106 H04 IVA 06/25/1985 07/29/1985 $720 $720 $0 -  
3. 01003 Serious 19100307 B 06/25/1985 07/29/1985 $630 $630 $0 -  
4. 02001 Other 19100106 E09 II 06/25/1985 06/27/1985 $0 $0 $0 -  

Investigation Summary

Investigation Nr: 14332282
Event: 06/04/1985
EMPLOYEES INJURED WHEN TOLUENE VAPORS WERE IGNITED

AN EXPLOSION IN A TOLUENE RECOVERY ROOM BLEW OUT A PORTION OF THE BUILDING'S ROOF AND PARTS OF ALL FOUR WALLS. THE TOLUENE RECOVERY SYTEM BEING USED WAS A VIC 512 VAPOR ADSORBTION SYSTEM. THE ROOM WAS NOT PROPERLY VENTILATED. (THE DECANTER ATMOSPHERIC VENTS WERE VENTED BACK INTO THE ROOM). THERE WERE NO EMPLOYEES IN THE ROOM AT THE TIME OF THE EXPLOSION, BUT SEVERAL WERE WORKING CLOSE BY. EMPLOYEE #1 WAS HOSPITALIZED FOR SECOND DEGREE BURNS ON HER ARMS AND LEGS. ALL THE OTHER INJURED EMPLOYEES RECEIVED LACERATIONS, ABRASIONS, AND SOME SMOKE INHALATION INJURIES. NONE OF THESE EMPLOYEES WERE HOSPITALIZED. THE SOURCE OF IGNITION IS UNKNOWN, BUT THOUGHT TO BE LOCATED OUTSIDE THE TOLUENE RECOVERY ROOM.

Keywords: BURN, FLAMMABLE VAPORS, TOLUENE, EXPLOSION, LACERATION, ABRASION, ARM, SMOKE INHALATION, LEG

Investigated Inspection
# Inspection Age Sex Degree of Injury Nature of Injury Occupation
1 2173995 Hospitalized injury Burn/Scald(Heat) Occupation not reported
2 2173995 Non Hospitalized injury Other Occupation not reported
3 2173995 Non Hospitalized injury Bruise/Contus/Abras Occupation not reported
4 2173995 Non Hospitalized injury Burn/Scald(Heat) Occupation not reported
5 2173995 Non Hospitalized injury Cut/Laceration Occupation not reported
6 2173995 Non Hospitalized injury Cut/Laceration Occupation not reported
7 2173995 Non Hospitalized injury Cut/Laceration Occupation not reported
8 2173995 Non Hospitalized injury Bruise/Contus/Abras Occupation not reported
9 2173995 Non Hospitalized injury Other Occupation not reported
Back to Top

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.