Inspection Detail
Inspection: 2172427 - Odc, Inc.
Inspection Information - Office: Atlanta East Area Office
Site Address:
Odc, Inc.
4291 Communications Drive
Norcross, GA 30093
Mailing Address:
4291 Communications Drive, Norcross, GA 30093
Union Status: NonUnion
SIC:2295
NAICS: 0
Inspection Type: Referral
Scope: Partial
Advanced Notice: N
Ownership: Private
Safety/Health: Safety
Close Conference: 06/24/1985
Planning Guide: Safety-Manufacturing
Emphasis:
Case Closed: 07/10/1985
| Type | Activity Nr | Safety | Health |
|---|---|---|---|
| Referral | 900966060 | Yes |
| Violations/Penalties | Serious | Willful | Repeat | Other | Unclass | Total |
|---|---|---|---|---|---|---|
| Initial Violations | 5 | 5 | ||||
| Current Violations | 5 | 5 | ||||
| Initial Penalty | $0 | $0 | $0 | $0 | $0 | $0 |
| Current Penalty | $0 | $0 | $0 | $0 | $0 | $0 |
| FTA Penalty | $0 | $0 | $0 | $0 | $0 | $0 |
| # | Citation ID | Citaton Type | Standard Cited | Issuance Date | Abatement Due Date | Current Penalty | Initial Penalty | FTA Penalty | Contest | Latest Event | Note |
|---|---|---|---|---|---|---|---|---|---|---|---|
| 1. | 01001 | Other | 19040002 A | 07/16/1985 | 08/09/1985 | $0 | $0 | $0 | - | ||
| 2. | 01002 | Other | 19100020 G01 I | 07/16/1985 | 08/30/1985 | $0 | $0 | $0 | - | ||
| 3. | 01003 | Other | 19100020 G02 | 07/16/1985 | 08/30/1985 | $0 | $0 | $0 | - | ||
| 4. | 01004 | Other | 19100106 H04 IVA | 07/16/1985 | 08/30/1985 | $0 | $0 | $0 | - | ||
| 5. | 01005 | Other | 19100106 H07 I | 07/16/1985 | 08/30/1985 | $0 | $0 | $0 | - |
Investigation Summary
AN EMPLOYEE WAS FILLING A 55-GALLON DRUM WITH TOLUENE SOLVENT FOR USE IN A COATING MIX. A 1-INCH-DIAMETER HOSE WAS DISPENSING THE SOLVENT. WHEN THE DRUM WAS ABOUT HALF FULL, THE SOLVENT IGNITED BECAUSE OF A STATIC DISCHARGE. THE EMPLOYEE RECEIVED FIRST DEGREE BURNS TO HIS FACE AND HANDS. (THE FIRE DID NO FURTHER DAMAGE, AS IT WAS PUT OUT WITH PORTABLE FIRE EXTINGUISHERS.) THE HOSE BEING USED TO DISPENSE THE SOLVENT WAS TESTED WITH A VOLT-OHM METER AND WAS FOUND NOT TO PROVIDE ELECTRICAL CONTINUITY.
Keywords: BURN, STATIC ELECTRICITY, ELECTRICAL, FLAMMABLE LIQUID, E GI VII, FIRE, TOLUENE, EXPLOSION, FACE, HAND
| # | Inspection | Age | Sex | Degree of Injury | Nature of Injury | Occupation |
|---|---|---|---|---|---|---|
| 1 | 2172427 | Non Hospitalized injury | Burn/Scald(Heat) | Occupation not reported |
Translate