Inspection Detail
Inspection: 2035780 - Alcan Sheet And Plate Div Of Alcan Alum Corp
Inspection Information - Office: Syracuse Area Office
Site Address: 
			   Alcan Sheet And Plate Div Of Alcan Alum Corp
			   Lake Road North
Oswego, NY 13126
Mailing Address: 
			   P O Box 28, Oswego, NY 13126
Union Status: NonUnion
SIC:3353
NAICS: 0
Inspection Type: Accident
Scope: Partial
Advanced Notice: N
Ownership: Private
Safety/Health: Safety
Close Conference: 09/18/1985
Emphasis:
Case Closed: 09/18/1985
| Type | Activity Nr | Safety | Health | 
|---|---|---|---|
| Accident | 360528699 | 
Investigation Summary
A COMBUSTIBLE MIXTURE WAS HEATED ABOVE THE EXPLOSIVE LEVEL IN A FURNACE. AN EXPLOSION INJURED EMPLOYEES # 1 THROUGH #5.
Keywords: FURNACE, EXPLOSION, COMBUSTIBLE LIQUID, OVERHEATED
| # | Inspection | Age | Sex | Degree of Injury | Nature of Injury | Occupation | 
|---|---|---|---|---|---|---|
| 1 | 2035780 | Hospitalized injury | Other | Occupation not reported | ||
| 2 | 2035780 | Hospitalized injury | Other | Occupation not reported | ||
| 3 | 2035780 | Hospitalized injury | Other | Occupation not reported | ||
| 4 | 2035780 | Hospitalized injury | Other | Occupation not reported | ||
| 5 | 2035780 | Hospitalized injury | Other | Occupation not reported | 