Powered by GoogleTranslate

Inspection Detail

Inspection: 2035780 - Alcan Sheet And Plate Div Of Alcan Alum Corp

Inspection Information - Office: Syracuse Area Office

 

Inspection Nr: 2035780
Report ID: 0215800
Date Opened: 03/21/1985

Site Address:
Alcan Sheet And Plate Div Of Alcan Alum Corp
Lake Road North
Oswego, NY 13126

Mailing Address:
P O Box 28, Oswego, NY 13126

Union Status: NonUnion

SIC:3353

NAICS: 0 


Inspection Type: Accident

Scope: Partial

Advanced Notice: N

Ownership: Private

Safety/Health: Safety

Close Conference: 09/18/1985

Emphasis:

Case Closed: 09/18/1985


Related Activity
Type Activity Nr Safety Health
Accident 360528699

Investigation Summary

Investigation Nr: 14489512
Event: 03/21/1985
EXPLOSION IN A FURNACE

A COMBUSTIBLE MIXTURE WAS HEATED ABOVE THE EXPLOSIVE LEVEL IN A FURNACE. AN EXPLOSION INJURED EMPLOYEES # 1 THROUGH #5.

Keywords: FURNACE, EXPLOSION, COMBUSTIBLE LIQUID, OVERHEATED

Investigated Inspection
# Inspection Age Sex Degree of Injury Nature of Injury Occupation
1 2035780 Hospitalized injury Other Occupation not reported
2 2035780 Hospitalized injury Other Occupation not reported
3 2035780 Hospitalized injury Other Occupation not reported
4 2035780 Hospitalized injury Other Occupation not reported
5 2035780 Hospitalized injury Other Occupation not reported
Back to Top

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.