Powered by GoogleTranslate

Inspection Detail

Inspection: 1960178 - Atlanta Elevator Erectors, Inc.

Inspection Information - Office: Atlanta East Area Office

 

Inspection Nr: 1960178
Report ID: 0418100
Date Opened: 02/04/1985

Site Address:
Atlanta Elevator Erectors, Inc.
45 Edgewood Avenue
Atlanta, GA 30303

Mailing Address:
1600 Candler Bldg., 127 Peachtree St. N. E., Atlanta, GA 30043

Union Status: Union

SIC:1796

NAICS: 0 


Inspection Type: Unprog Rel

Scope: Complete

Advanced Notice: N

Ownership: Private

Safety/Health: Safety

Close Conference: 02/07/1985

Planning Guide: Safety-Construction

Emphasis:

Case Closed: 03/24/1987


Related Activity
Type Activity Nr Safety Health
Accident 360538458
Violation Summary
Violations/Penalties Serious Willful Repeat Other Unclass Total
Initial Violations 1 1
Current Violations 1 1
Initial Penalty $490 $0 $0 $0 $0 $490
Current Penalty $200 $0 $0 $0 $0 $200
FTA Penalty $0 $0 $0 $0 $0 $0

Violation Items
# Citation ID Citaton Type Standard Cited Issuance Date Abatement Due Date Current Penalty Initial Penalty FTA Penalty Contest Latest Event Note
1. 01001A Serious 19260552 D 03/06/1985 03/09/1985 $200 $490 $0 03/26/1985 J - ALJ Decision  
2. 01001B Serious 19260552 D 03/06/1985 03/09/1985 $0 $0 $0 03/26/1985 -  

Investigation Summary

Investigation Nr: 14543128
Event: 02/01/1985
Employee killed in fall down elevator shaft

Employee #1 and five coworkers rode the Otis freight elevator from the third to the ninth floor. The elevator operator got out of the car and held the hoistway door open. As Employee #1 was exiting, the extension cord he had coiled around his left shoulder became caught on the elevator control, holding it in the 'up' position. The elevator car started up, pulling him into the shaft. He fell to the bottom of the pit, suffering multiple head and body injuries. Employee #1 was killed. The freight elevator had been installed in April, 1924. It had a toggle-type deadman control which, when pushed and held in one direction, took the elevator up, and vice versa. The elevator was being changed to a pulley automatic system. New hoistway doors had been installed but were not yet interlocked, so the elevator was able to move even though the doors were open. The elevator car gate had also been removed.

Keywords: DEADMAN CONTROL, ELEVATOR SHAFT, ELEVATOR GATE, ELEVATOR, FALL, WORK RULES, CONSTRUCTION, INTERLOCK

Investigated Inspection
# Inspection Age Sex Degree of Injury Nature of Injury Occupation
1 1960178 Occupation Not Listed
Back to Top

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.

Close