Inspection Detail
Inspection: 1942812 - General Motors Corp Harrison Radiator Div
Inspection Information - Office: Cincinnati Area Office
Site Address:
General Motors Corp Harrison Radiator Div
S Dryden Rd
Moraine, OH 45439
Mailing Address:
Po Box 824, Dayton, OH 45401
Union Status: Union
SIC:3585
NAICS: 0
Inspection Type: Accident
Scope: Partial
Advanced Notice: N
Ownership: Private
Safety/Health: Safety
Close Conference: 09/24/1984
Planning Guide: Safety-Manufacturing
Emphasis:
Case Closed: 07/02/1986
Type | Activity Nr | Safety | Health |
---|---|---|---|
Accident | 360648463 |
Violations/Penalties | Serious | Willful | Repeat | Other | Unclass | Total |
---|---|---|---|---|---|---|
Initial Violations | 1 | 1 | ||||
Current Violations | 1 | 1 | ||||
Initial Penalty | $0 | $9,000 | $0 | $0 | $0 | $9,000 |
Current Penalty | $900 | $0 | $0 | $0 | $0 | $900 |
FTA Penalty | $0 | $0 | $0 | $0 | $0 | $0 |
# | Citation ID | Citaton Type | Standard Cited | Issuance Date | Abatement Due Date | Current Penalty | Initial Penalty | FTA Penalty | Contest | Latest Event | Note |
---|---|---|---|---|---|---|---|---|---|---|---|
1. | 01001 | Serious | 5A0001 | 12/05/1984 | 01/07/1985 | $900 | $9,000 | $0 | I - Informal Settlement |
Investigation Summary
ON SEPTEMBER 14, 1984, AT APPROXIMATELY 7:10 AM, EMPLOYEE #1 CLIMBED INTO THE HOUSING OF THE NUMBER 11 DRAG CHAIN CONVEYOR, LOCATED OVERHEAD ON THE MAIN FLOOR OF THE POWERHOUSE. THE ELECTRICAL POWER DISCONNECT FOR THIS CONVEYOR WAS NOT LOCKED OUT AND TAGGED. THE CONVEYOR WAS SOMEHOW ACTIVATED, ALLOWING A DRAG BUCKET TO MOVE. THE DRAG BUCKET CAUGHT THE EMPLOYEE IN THE UPPER BACK AREA, PULLING HIM AGAINST THE STATIONARY HOUSING AND OVER THE SPROCKET END OF THE CONVEYOR.
Keywords: DRAG CHAIN CONVEYOR, LOCKOUT, CRUSHED, CONVEYOR, SPROCKET, DISCONNECTING MEANS
# | Inspection | Age | Sex | Degree of Injury | Nature of Injury | Occupation |
---|---|---|---|---|---|---|
1 | 1942812 | Fatality | Fracture | Occupation not reported |