Inspection: 1915271 - Butler Johnson Inc Rig #3

Inspection Information - Office: Austin Area Office

 

Inspection Nr: 1915271
Report ID: 0625400
Date Opened: 05/08/1985

Site Address:
Butler Johnson Inc Rig #3
Tx Hwy 164 4 Mi E Of
Groesbeck, TX 76642

Mailing Address:
600 Travis Place, Shreveport, LA 71101

Union Status: NonUnion

SIC:1381

NAICS: 0 


Inspection Type: Accident

Scope: Partial

Advanced Notice: N

Ownership: Private

Safety/Health: Safety

Close Conference: 05/10/1985

Emphasis: L:Oilgas

Case Closed: 10/01/1986


Related Activity
Type Activity Nr Safety Health
Accident 360671028
Violation Summary
Violations/Penalties Serious Willful Repeat Other Unclass Total
Initial Violations 3 3
Current Violations 3 3
Initial Penalty $1,040 $0 $0 $0 $0 $1,040
Current Penalty $1,600 $0 $0 $0 $0 $1,600
FTA Penalty $0 $0 $0 $0 $0 $0

Violation Items
# Citation ID Citaton Type Standard Cited Issuance Date Abatement Due Date Current Penalty Initial Penalty FTA Penalty Contest Latest Event Note
1. 01001A Serious 19100219 D01 06/10/1985 06/13/1985 $480 $480 $0 -  
2. 01001B Serious 19100219 E01 I 06/10/1985 06/13/1985 $0 $0 $0 -  
3. 01002 Serious 19100303 B01 06/10/1985 06/13/1985 $560 $0 $0 -  
4. 01003A Serious 19100304 A03 06/10/1985 06/13/1985 $560 $560 $0 -  
5. 01003B Serious 19100304 F05 V 06/10/1985 06/13/1985 $0 $0 $0 -  

Investigation Summary

Investigation Nr: 14511141
Event: 05/07/1985
ELECTRIC SHOCK - GROUND FAULT IN STEAM CLEANER

Two oil well drilling employees were using a Delco portable steam cleaner. One of the employees was holding the steam nozzle while the second employee plugged the cleaner into an extension cord set. The employee holding the nozzle, who was standing in water and mud, was electrocuted. The plug on the steam cleaner's power supply cord had been wired with the ungrounded circuit conductor and the equipment grounding conductor reversed. This ground fault energized the frame of the cleaner and the pressure nozzle (through the metal-clad pressure hose). The equipment was not approved for wet or conductive locations. It was regularly rewired and taped when water would cause employees to receive electric shocks.

Keywords: E GI V, STEAM CLEANER, ELECTRICAL, ELECTROCUTED, GROUND FAULT, WET OPERATION, EQUIPMENT GROUNDING

Investigated Inspection
# Inspection Age Sex Degree of Injury Nature of Injury Occupation
1 1915271 Fatality Electric Shock Occupation not reported
Back to Top

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.