Inspection Detail
Inspection: 1915271 - Butler Johnson Inc Rig #3
Inspection Information - Office: Austin Area Office
Site Address:
Butler Johnson Inc Rig #3
Tx Hwy 164 4 Mi E Of
Groesbeck, TX 76642
Mailing Address:
600 Travis Place, Shreveport, LA 71101
Union Status: NonUnion
SIC:1381
NAICS: 0
Inspection Type: Accident
Scope: Partial
Advanced Notice: N
Ownership: Private
Safety/Health: Safety
Close Conference: 05/10/1985
Emphasis: L:Oilgas
Case Closed: 10/01/1986
| Type | Activity Nr | Safety | Health |
|---|---|---|---|
| Accident | 360671028 |
| Violations/Penalties | Serious | Willful | Repeat | Other | Unclass | Total |
|---|---|---|---|---|---|---|
| Initial Violations | 3 | 3 | ||||
| Current Violations | 3 | 3 | ||||
| Initial Penalty | $1,040 | $0 | $0 | $0 | $0 | $1,040 |
| Current Penalty | $1,600 | $0 | $0 | $0 | $0 | $1,600 |
| FTA Penalty | $0 | $0 | $0 | $0 | $0 | $0 |
| # | Citation ID | Citaton Type | Standard Cited | Issuance Date | Abatement Due Date | Current Penalty | Initial Penalty | FTA Penalty | Contest | Latest Event | Note |
|---|---|---|---|---|---|---|---|---|---|---|---|
| 1. | 01001A | Serious | 19100219 D01 | 06/10/1985 | 06/13/1985 | $480 | $480 | $0 | - | ||
| 2. | 01001B | Serious | 19100219 E01 I | 06/10/1985 | 06/13/1985 | $0 | $0 | $0 | - | ||
| 3. | 01002 | Serious | 19100303 B01 | 06/10/1985 | 06/13/1985 | $560 | $0 | $0 | - | ||
| 4. | 01003A | Serious | 19100304 A03 | 06/10/1985 | 06/13/1985 | $560 | $560 | $0 | - | ||
| 5. | 01003B | Serious | 19100304 F05 V | 06/10/1985 | 06/13/1985 | $0 | $0 | $0 | - |
Investigation Summary
Two oil well drilling employees were using a Delco portable steam cleaner. One of the employees was holding the steam nozzle while the second employee plugged the cleaner into an extension cord set. The employee holding the nozzle, who was standing in water and mud, was electrocuted. The plug on the steam cleaner's power supply cord had been wired with the ungrounded circuit conductor and the equipment grounding conductor reversed. This ground fault energized the frame of the cleaner and the pressure nozzle (through the metal-clad pressure hose). The equipment was not approved for wet or conductive locations. It was regularly rewired and taped when water would cause employees to receive electric shocks.
Keywords: E GI V, STEAM CLEANER, ELECTRICAL, ELECTROCUTED, GROUND FAULT, WET OPERATION, EQUIPMENT GROUNDING
| # | Inspection | Age | Sex | Degree of Injury | Nature of Injury | Occupation |
|---|---|---|---|---|---|---|
| 1 | 1915271 | Fatality | Electric Shock | Occupation not reported |
Translate