Inspection Detail
Inspection: 1908516 - Superior Snubbing Control
Inspection Information - Office: Austin Area Office
Site Address:
Superior Snubbing Control
2 Miles South On Hwy 237
Round Top, TX 78954
Mailing Address:
12930 Emmett Rd, Houston, TX 77091
Union Status: NonUnion
SIC:1389
NAICS: 0
Inspection Type: Accident
Scope: Partial
Advanced Notice: N
Ownership: Private
Safety/Health: Safety
Close Conference: 12/27/1984
Emphasis: L:Oilgas
Case Closed: 12/27/1984
| Type | Activity Nr | Safety | Health |
|---|---|---|---|
| Accident | 360549851 |
Investigation Summary
EMPLOYEES #1 THROUGH 5 WERE CHANGING OUT WELL HEAD EQUIPMENT ON A DISCHARGING HIGH-PRESSURE GAS WELL. THE GAS REACHED A CRANE ENGINE LOCATION. AN EMERGENCY ACTION BY A CRANE HAND CAUSED THE ENGINE TO BACKFIRE. THE GAS IGNITED, BURNING EMPLOYEES 1 - 5. A SPECTACULAR FIRE CONTINUED FOR 3 DAYS.
Keywords: BURN, GAS WELL, FIRE, NATURAL GAS, WELLHEAD
| # | Inspection | Age | Sex | Degree of Injury | Nature of Injury | Occupation |
|---|---|---|---|---|---|---|
| 1 | 1908516 | Hospitalized injury | Burn/Scald(Heat) | Occupation not reported |
Translate