Inspection Detail
Inspection: 1903442 - Senior Drilling Company Inc Rig 40
Inspection Information - Office: Austin Area Office
Site Address:
Senior Drilling Company Inc Rig 40
Heci Francine 1 Well 2 Mi Sw Of
Carmine, TX 78932
Mailing Address:
Route 6 Box 777, Breaux Bridge, LA 70517
Union Status: NonUnion
SIC:1381
NAICS: 0
Inspection Type: Accident
Scope: Complete
Advanced Notice: Y
Ownership: Private
Safety/Health: Safety
Close Conference: 01/18/1985
Emphasis: L:Oilgas
Case Closed: 10/01/1986
| Type | Activity Nr | Safety | Health |
|---|---|---|---|
| Accident | 360549513 |
| Violations/Penalties | Serious | Willful | Repeat | Other | Unclass | Total |
|---|---|---|---|---|---|---|
| Initial Violations | 2 | 7 | 9 | |||
| Current Violations | 2 | 7 | 9 | |||
| Initial Penalty | $400 | $0 | $0 | $0 | $0 | $400 |
| Current Penalty | $400 | $0 | $0 | $0 | $0 | $400 |
| FTA Penalty | $0 | $0 | $0 | $0 | $0 | $0 |
| # | Citation ID | Citaton Type | Standard Cited | Issuance Date | Abatement Due Date | Current Penalty | Initial Penalty | FTA Penalty | Contest | Latest Event | Note |
|---|---|---|---|---|---|---|---|---|---|---|---|
| 1. | 01001 | Serious | 19100304 F04 | 02/15/1985 | 02/19/1985 | $240 | $240 | $0 | - | ||
| 2. | 01002 | Serious | 19100307 B | 02/15/1985 | 02/19/1985 | $160 | $160 | $0 | - | ||
| 3. | 02001 | Other | 19030002 A01 | 02/15/1985 | 02/19/1985 | $0 | $0 | $0 | - | ||
| 4. | 02002 | Other | 19040002 A | 02/15/1985 | 02/19/1985 | $0 | $0 | $0 | - | ||
| 5. | 02003 | Other | 19040008 | 02/15/1985 | 02/19/1985 | $0 | $0 | $0 | - | ||
| 6. | 02004 | Other | 19100151 B | 02/15/1985 | 02/19/1985 | $0 | $0 | $0 | - | ||
| 7. | 02005 | Other | 19100212 A01 | 02/15/1985 | 02/26/1985 | $0 | $0 | $0 | - | ||
| 8. | 02006 | Other | 19100305 A02 IIIG | 02/15/1985 | 02/22/1985 | $0 | $0 | $0 | - | ||
| 9. | 02007 | Other | 19100305 G02 III | 02/15/1985 | 02/26/1985 | $0 | $0 | $0 | - |
Investigation Summary
A SKID-MOUNTED TRIPLEX PUMP DRIVEN BY A 3-HORSEPOWER ELECTRIC MOTOR WAS TO BE USED IN THE CLEANING OF A DRILLING RIG. THE MOTOR WAS SUPPLIED BY A 3-CONDUCTOR, 240-VOLT GROUNDED CIRCUIT. THE DRILLING RIG WAS CLEANED WITH HIGH PRESSURE WATER FROM THE PUMP, CALLED THE RIG WASH-DOWN PUMP. AN EMPLOYEE HAD BEEN SCRUBBING THE RIG WITH A SCRUB BRUSH AND SOAPY SOLUTION, AND HE WAS VERY WET. AFTER HE FINISHED SCRUBBING, HE PICKED UP THE METAL PUMP HOSE NOZZLE. WHEN HE TURNED ON THE ELECTRIC POWER, HE WAS ELECTROCUTED. INVESTIGATION REVEALED THAT THE GROUNDING CONDUCTOR IN THE SUPPLY CORD FOR THE PUMP MOTOR WAS NOT CONTINUOUS FROM THE RECEPTACLE TO THE PUMP MOTOR. ADDITIONALLY, THE MOTOR CASE HAD SHORTED TO THE MOTOR STATOR WINDINGS, AND THERE WAS ELECTRICAL CONTINUITY BETWEEN THE MOTOR CASE AND THE METAL NOZZLE THROUGH THE HOSE.
Keywords: ELECTRIC MOTOR, ELECTRICAL, E GI VII, ELECTROCUTED, GROUND FAULT, EQUIPMENT GROUNDING
| # | Inspection | Age | Sex | Degree of Injury | Nature of Injury | Occupation |
|---|---|---|---|---|---|---|
| 1 | 1903442 | Fatality | Electric Shock | Occupation not reported |
Translate