Inspection Detail
Inspection: 1899111 - Ard Drilling Co
Inspection Information - Office: Lubbock Area Office
Site Address:
Ard Drilling Co
Rig 7 19.5 Miles Northeast Of
Andrews, TX 79714
Mailing Address:
Po Box 1030, Midland, TX 79702
Union Status: NonUnion
SIC:1381
NAICS: 0
Inspection Type: Accident
Scope: Partial
Advanced Notice: Y
Ownership: Private
Safety/Health: Safety
Close Conference: 12/21/1984
Emphasis: L:Oilgas
Case Closed: 03/27/1985
Type | Activity Nr | Safety | Health |
---|---|---|---|
Accident | 360546675 |
Investigation Summary
An employee was on a drilling rig opening a jet valve. He apparently contacted an energized conductor and was electrocuted.
Keywords: E GI III, ELECTRICAL, ELECTROCUTED, ELECTRIC CONDUCTOR, UNTRAINED, OIL RIG
# | Inspection | Age | Sex | Degree of Injury | Nature of Injury | Occupation |
---|---|---|---|---|---|---|
1 | 1899111 | Fatality | Electric Shock | Occupation not reported |