Inspection Detail
Inspection: 18872242 - National Asbestos Removal, Inc.
Inspection Information - Office: Department Of Labor, Licensing, And Regulation Division Of Labor And Industry Maryland Occupational Safety And Health
Site Address:
National Asbestos Removal, Inc.
Governor'S Square, 409 A Muddy Branch Road
Gaithersburg, MD 20760
Mailing Address:
10111 B Bacon Drive, Beltsville, MD 20705
Union Status: NonUnion
SIC:1522
NAICS: 0
Inspection Type: Accident
Scope: Partial
Advanced Notice: N
Ownership: Private
Safety/Health: Health
Close Conference: 04/22/1987
Planning Guide: Health-Construction
Emphasis:
Case Closed: 10/01/1987
| Type | Activity Nr | Safety | Health |
|---|---|---|---|
| Accident | 360618052 |
| Violations/Penalties | Serious | Willful | Repeat | Other | Unclass | Total |
|---|---|---|---|---|---|---|
| Initial Violations | 5 | 12 | 17 | |||
| Current Violations | 1 | 6 | 7 | |||
| Initial Penalty | $2,450 | $0 | $0 | $300 | $0 | $2,750 |
| Current Penalty | $850 | $0 | $0 | $0 | $0 | $850 |
| FTA Penalty | $0 | $0 | $0 | $0 | $0 | $0 |
| # | Citation ID | Citaton Type | Standard Cited | Issuance Date | Abatement Due Date | Current Penalty | Initial Penalty | FTA Penalty | Contest | Latest Event | Note |
|---|---|---|---|---|---|---|---|---|---|---|---|
| 1. | 01001 | Serious | 19260055 A | 05/11/1987 | 05/14/1987 | $400 | $400 | $0 | 06/05/1987 | F - Formal Settlement | Citation has been deleted. |
| 2. | 02001 | Serious | 19260055 B | 05/11/1987 | 05/14/1987 | $400 | $400 | $0 | 06/05/1987 | F - Formal Settlement | Citation has been deleted. |
| 3. | 03001 | Serious | 19260103 A 2 | 05/11/1987 | 05/14/1987 | $400 | $400 | $0 | 06/05/1987 | F - Formal Settlement | Citation has been deleted. |
| 4. | 04001 | Serious | 19100134 B 8 | 05/11/1987 | 05/14/1987 | $400 | $400 | $0 | 06/05/1987 | F - Formal Settlement | Citation has been deleted. |
| 5. | 05001 | Other | 890032 E B | 05/11/1987 | 05/14/1987 | $50 | $50 | $0 | 06/05/1987 | F - Formal Settlement | Citation has been deleted. |
| 6. | 05002 | Other | 890032 F A | 05/11/1987 | 05/14/1987 | $50 | $50 | $0 | 06/05/1987 | F - Formal Settlement | Citation has been deleted. |
| 7. | 05003 | Other | 890032 H A | 05/11/1987 | 05/14/1987 | $50 | $50 | $0 | 06/05/1987 | F - Formal Settlement | Citation has been deleted. |
| 8. | 05004 | Other | 890032 M B | 05/11/1987 | 05/14/1987 | $50 | $50 | $0 | 06/05/1987 | F - Formal Settlement | Citation has been deleted. |
| 9. | 05005 | Other | 09123102 A | 05/11/1987 | 05/14/1987 | $50 | $50 | $0 | 06/05/1987 | F - Formal Settlement | Citation has been deleted. |
| 10. | 05006 | Other | 09123107 A 1 | 05/11/1987 | 05/14/1987 | $50 | $50 | $0 | 06/05/1987 | F - Formal Settlement | Citation has been deleted. |
| 11. | 06001A | Serious | 19260055 A | 05/11/1987 | 05/14/1987 | $850 | $850 | $0 | - | ||
| 12. | 06001B | Serious | 19260055 B | 05/11/1987 | 05/14/1987 | $0 | $0 | $0 | - | ||
| 13. | 06001C | Serious | 19260103 A 2 | 05/11/1987 | 05/14/1987 | $0 | $0 | $0 | - | ||
| 14. | 07001 | Other | 890032 E B | 05/11/1987 | 05/14/1987 | $0 | $0 | $0 | - | ||
| 15. | 07002 | Other | 890032 F A | 05/11/1987 | 05/14/1987 | $0 | $0 | $0 | - | ||
| 16. | 07003 | Other | 890032 H A | 05/11/1987 | 05/14/1987 | $0 | $0 | $0 | - | ||
| 17. | 07004 | Other | 890032 M B | 05/11/1987 | 05/14/1987 | $0 | $0 | $0 | - | ||
| 18. | 07005 | Other | 09123102 A | 05/11/1987 | 05/14/1987 | $0 | $0 | $0 | - | ||
| 19. | 07006 | Other | 09123107 A 1 | 05/11/1987 | 05/14/1987 | $0 | $0 | $0 | - |
Investigation Summary
WHILE ASBESTOS INSULATION WAS BEING REMOVED, SEVERAL HOLES WERE UNCOVERED IN THE EXHAUST DUCT. THESE HOLES PERMITTED EXHAUST FUMES TO RETURN TO THE BOILERS, THUS CAUSING INCOMPLETE COMBUSTION. EMPLOYEES #1-5, WHO WERE WORKING IN THE ENCLOSURE, WERE EXPOSED TO HIGH LEVELS OF CARBON MONOXIDE. THE EMPLOYEES WERE WEARING WILLSON HALF-FACE, NEGATIVE PRESSURE RESPIRATORS. THE EMPLOYER ATTEMPTED TO FURTHER VENTILATE THE ENCLOSURE, BUT THE VENTILATION SYSTEM DID NOT REDUCE THE EXPOSURE LEVELS.
Keywords: VENTILATION, CONFINED SPACE, PPE, EXHAUST FUMES, ASBESTOS REMOVAL, CARBON MONOXIDE, RESPIRATOR
| # | Inspection | Age | Sex | Degree of Injury | Nature of Injury | Occupation |
|---|---|---|---|---|---|---|
| 1 | 18872242 | Hospitalized injury | Asphyxia | Insulation Workers | ||
| 2 | 18872242 | Non Hospitalized injury | Asphyxia | Insulation Workers | ||
| 3 | 18872242 | Non Hospitalized injury | Asphyxia | Insulation Workers | ||
| 4 | 18872242 | Non Hospitalized injury | Asphyxia | Insulation Workers | ||
| 5 | 18872242 | Non Hospitalized injury | Asphyxia | Insulation Workers |