Inspection Detail
Inspection: 18856690 - M & W Construction Systems, Inc
Inspection Information - Office: Department Of Labor, Licensing, And Regulation Division Of Labor And Industry Maryland Occupational Safety And Health
Site Address:
M & W Construction Systems, Inc
0840 Annapolis Junction Road
Annapolis Jct., MD 20710
Mailing Address:
5635 Furnace Avenue, Elkridge, MD 21227
Union Status: NonUnion
SIC:1761
NAICS: 0
Inspection Type: Accident
Scope: Partial
Advanced Notice: N
Ownership: Private
Safety/Health: Safety
Close Conference: 01/05/1988
Planning Guide: Safety-Construction
Emphasis:
Case Closed: 02/17/1988
| Type | Activity Nr | Safety | Health |
|---|---|---|---|
| Accident | 360751713 |
| Violations/Penalties | Serious | Willful | Repeat | Other | Unclass | Total |
|---|---|---|---|---|---|---|
| Initial Violations | 2 | 2 | ||||
| Current Violations | 2 | 2 | ||||
| Initial Penalty | $860 | $0 | $0 | $0 | $0 | $860 |
| Current Penalty | $650 | $0 | $0 | $0 | $0 | $650 |
| FTA Penalty | $0 | $0 | $0 | $0 | $0 | $0 |
| # | Citation ID | Citaton Type | Standard Cited | Issuance Date | Abatement Due Date | Current Penalty | Initial Penalty | FTA Penalty | Contest | Latest Event | Note |
|---|---|---|---|---|---|---|---|---|---|---|---|
| 1. | 01001 | Serious | 890032 A | 01/22/1988 | 01/25/1988 | $400 | $490 | $0 | I - Informal Settlement | ||
| 2. | 02001 | Serious | 19260500 B 4 | 01/22/1988 | 01/25/1988 | $250 | $370 | $0 | I - Informal Settlement |
Investigation Summary
Employee #1 was standing near a 31 in. roof opening. He was one of a crew that was installing approximately 32 in. wide by 96 in. long by 2 in. thick roof panels weighing approximately 100 lb. The panels were placed into bulb tee slots at right angles to bar joists. The bar joists were 5 ft apart of the tees, which were 30 1/2 in. apart. The rooftop was approximately 22 ft above a 6 in. thick poured concrete deck. The equipment was Permadeck panels of wood fibers/Portland cement banded under pressure. Employee #1's right foot was on a previously installed panel and his left foot was on a steel purlin. He slipped and fell to his death, sustaining head, neck, and shoulder injuries. All workers, including Employee #1, had received training but no ppe was used. Causal factors related to the accident include misjudgment of a hazardous condition and lack of ppe, such as a catch platform/scaffold beneath the roof opening.
Keywords: HEAD, INSTALLING, ROOF, WORK RULES, SLIP, CONSTRUCTION, FALL, FALL PROTECTION, ROOF OPENING
| # | Inspection | Age | Sex | Degree of Injury | Nature of Injury | Occupation |
|---|---|---|---|---|---|---|
| 1 | 18856690 | Fatality | Other | Roofers |