Inspection Detail
Inspection: 18701102 - Obras Publicas Municipales De Mayaguez
Inspection Information - Office: Pr-E-Mayaguez 0257240
Site Address:
Obras Publicas Municipales De Mayaguez
Calle Pablo Casals, Estacionamiento Municipal
Mayaguez, PR 00708
Mailing Address:
Apartado 447, Mayaguez, PR 00708
Union Status: NonUnion
SIC:1721
NAICS: 0
Inspection Type: Accident
Scope: Partial
Advanced Notice: N
Ownership: LocalGovt
Safety/Health: Safety
Close Conference: 03/30/1988
Emphasis:
Case Closed: 06/06/1988
Type | Activity Nr | Safety | Health |
---|---|---|---|
Accident | 360109086 |
Violations/Penalties | Serious | Willful | Repeat | Other | Unclass | Total |
---|---|---|---|---|---|---|
Initial Violations | 2 | 2 | ||||
Current Violations | 2 | 2 | ||||
Initial Penalty | $0 | $0 | $0 | $0 | $0 | $0 |
Current Penalty | $0 | $0 | $0 | $0 | $0 | $0 |
FTA Penalty | $0 | $0 | $0 | $0 | $0 | $0 |
# | Citation ID | Citaton Type | Standard Cited | Issuance Date | Abatement Due Date | Current Penalty | Initial Penalty | FTA Penalty | Contest | Latest Event | Note |
---|---|---|---|---|---|---|---|---|---|---|---|
1. | 01001 | Serious | 19260021 B02 | 04/06/1988 | 04/10/1988 | $0 | $0 | $0 | - | ||
2. | 01002A | Serious | 19260416 A01 | 04/06/1988 | 04/10/1988 | $0 | $0 | $0 | - | ||
3. | 01002B | Serious | 19260416 A03 | 04/06/1988 | 04/10/1988 | $0 | $0 | $0 | - | ||
4. | 01002C | Serious | 19260416 A03 | 04/06/1988 | 04/10/1988 | $0 | $0 | $0 | - |
Investigation Summary
A PAINTER WAS PAINTING A WALL OF A BUILDING. HE WAS USING AN ALUMINUM EXTENSION HANDLE TO EXTEND HIS REACH AS HE WAS PAINTING. THE EXTENSION HANDLE CONTACTED A 38-KILOVOLT OVERHEAD POWER LINE, AND THE PAINTER WAS ELECTROCUTED.
Keywords: OVERHEAD POWER LINE, ELECTRICAL, ELECTROCUTED, METAL POLE, E C, EXTENSION HANDLE, PAINTER
# | Inspection | Age | Sex | Degree of Injury | Nature of Injury | Occupation |
---|---|---|---|---|---|---|
1 | 18701102 | Fatality | Electric Shock | Painters, construction and maintenance |