Powered by GoogleTranslate

Inspection Detail

Inspection: 18690016 - Squibb Manufacturing Inc

Inspection Information - Office: Pr-E-Caguas 0257220

 

Inspection Nr: 18690016
Report ID: 0257220
Date Opened: 04/21/1987

Site Address:
Squibb Manufacturing Inc
Carr 3 Km 77.5
Humacao, PR 00791

Mailing Address:
Po Box 609, Humacao, PR 00791

Union Status: NonUnion

SIC:2834

NAICS: 0 


Inspection Type: Accident

Scope: Complete

Advanced Notice: N

Ownership: Private

Safety/Health: Safety

Close Conference: 05/06/1987

Planning Guide: Safety-Manufacturing

Emphasis:

Case Closed: 06/05/1987


Related Activity
Type Activity Nr Safety Health
Accident 360596928

Investigation Summary

Investigation Nr: 14460752
Event: 02/27/1987
EMPLOYEE BURNED IN FLASH FIRE

EMPLOYEE #1 WAS WASHING THE INTERIOR OF A DRYER, ASSISTED BY ANOTHER CHEMICAL OPERATOR. THEY WERE USING METHANOL AND A 2-PERCENT CAUSTIC SODA. AN UNKNOWN IGNITION SOURCE IGNITED THE VAPORS, CAUSING A FLASH FIRE WHICH FATALLY BURNED EMPLOYEE #1.

Keywords: BURN, CONFINED SPACE, FLAMMABLE VAPORS, CLEANING, FIRE, NATURAL GAS, CHEMICAL

Investigated Inspection
# Inspection Age Sex Degree of Injury Nature of Injury Occupation
1 18690016 Fatality Burn(Chemical) Chemical technicians
Back to Top

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.

Close