Inspection: 18690016 - Squibb Manufacturing Inc
Inspection Information - Office: Pr-E-Caguas 0257220
Site Address:
Squibb Manufacturing Inc
Carr 3 Km 77.5
Humacao, PR 00791
Mailing Address:
Po Box 609, Humacao, PR 00791
Union Status: NonUnion
SIC:2834
NAICS: 0
Inspection Type: Accident
Scope: Complete
Advanced Notice: N
Ownership: Private
Safety/Health: Safety
Close Conference: 05/06/1987
Planning Guide: Safety-Manufacturing
Emphasis:
Case Closed: 06/05/1987
| Type | Activity Nr | Safety | Health |
|---|---|---|---|
| Accident | 360596928 |
Investigation Summary
EMPLOYEE #1 WAS WASHING THE INTERIOR OF A DRYER, ASSISTED BY ANOTHER CHEMICAL OPERATOR. THEY WERE USING METHANOL AND A 2-PERCENT CAUSTIC SODA. AN UNKNOWN IGNITION SOURCE IGNITED THE VAPORS, CAUSING A FLASH FIRE WHICH FATALLY BURNED EMPLOYEE #1.
Keywords: BURN, CONFINED SPACE, FLAMMABLE VAPORS, CLEANING, FIRE, NATURAL GAS, CHEMICAL
| # | Inspection | Age | Sex | Degree of Injury | Nature of Injury | Occupation |
|---|---|---|---|---|---|---|
| 1 | 18690016 | Fatality | Burn(Chemical) | Chemical technicians |