Inspection Detail
Inspection: 18689570 - Carboline Comp.
Inspection Information - Office: Pr-E-Caguas 0257220
Site Address:
Carboline Comp.
Carr. 901m Km.2.7, Bo. Camino Nuevo
Humacao, PR 00661
Mailing Address:
P.O.Box 8055, Humacao, PR 00661
Union Status: NonUnion
SIC:1721
NAICS: 0
Inspection Type: Unprog Rel
Scope: Complete
Advanced Notice: N
Ownership: Private
Safety/Health: Safety
Close Conference: 07/21/1988
Planning Guide: Safety-Construction
Emphasis:
Case Closed: 08/08/1988
Investigation Summary
Employees that worked in the Sulfur Recovery Unit, Plant 2, suffered burns while loosening a condenser lid. Hot water and steam under pressure escaped, injuring Employees #1 through #7.
Keywords: COVER, STEAM, BURN, HIGH PRESSURE, HIGH TEMPERATURE, WATER
| # | Inspection | Age | Sex | Degree of Injury | Nature of Injury | Occupation |
|---|---|---|---|---|---|---|
| 1 | 18689570 | Occupation Not Listed |